5.7.3 Condition of ending defrosting operating
:
T outer panel
≥
12
℃
or defrosting time
≥
12 m, the compressor first meet condition stops
running until the two compressors meet the conditions.
6. Sleep function
6.1 When get to sleep mode, indoor wind speed will turn mute.
6.2 In cooling sleep operate mode, increase the temperature by 1
℃
after 1 hour
operation. and increase the temperature by 1
℃
after another 1 hour. Turn it off after 7
hours.
Refrigeration sleep operation
:
Temperature
Increase another 1
℃
Increase 1
℃
Original designed temperature
1h 2h 7h
(
Turn off after sleeping
)
6.3 In heating sleep operate mode, decrease the temperature by 2
℃
after 1 hour
operation. And decrease the temperature by another 2
℃
after 1 hour. Turn it off after 7
hours.
Heating operation sleep
:
Temperature
original designed temperature
decrease 2
℃
decrease another 2
℃
1h 2h 7h
(
Turn off after sleeping
)
6.4When the mode selection button is pressed. sleep function get cancelled.
6.5 Valid in cooling and heating mode. When sleep button is pressed. it can enter or
exit sleep mode.