![Premium GPAC12039 Service Manual Download Page 7](http://html.mh-extra.com/html/premium/gpac12039/gpac12039_service-manual_1596760007.webp)
5
Only under the mode of Heat and Fan, Press this button once, the LCD shows the
symbol,
the wetting function of the air conditioner is started. The initial humidity is 60%. Press the ”+”
or “-“ button once , the humidity increases or decreases 5%. The setting range is 30%~60%.
Press the button once again. The
symbol disappears. the function is cancelled at the
same time.
⑥
“TIMER/CLOCK” button
Setting the “ON/OFF” timer time
When remote controller is at the on/off state, Press this button, the LCD flickers the
symbol. Press the “+”or “-”button to set the timer time. After finishing it. Press
this button again in 10 seconds to affirm. If the setting time is the same as the current time,
this setting is invalid.
Press the button once more. The
symbol disappears. The function is
cancelled at the same time.
Adjusting the clock time
Press this button in 5 seconds under the state of no timer setting, the LCD flickers the
symbol. Press the “+” or “-” button to set the timer time, After finishing it, press this
button again in 10 seconds to affirm. If not, this operation is invalid.
⑦
“-” button
This button not only can adjust clock time and the timer time but also can set room humidity.
Adjusting clock time and timer time
Press it once .the time decreases one minute. Press it for 1 to 3 seconds, time display will
decrease at the speed of 2min/s.
For 3 to 5 seconds. It will decrease at the speed of 10min/s.
For more than 5 seconds. it will decrease at the speed of 10min/s.
Setting room temperature and room humidity
Press it once .the humidity decreases 5%.
⑧
Button
You can start the air-conditioner by pressing this button and stop its operation by pressing it
again.
⑨
“FEELING” button or “LOUVER” button
When it displays “FEELING” button:
Press this button can be used to set the feeling function.
The LCD shows the actual room temperature when the function set and it shows the setting
temperature when the function cancelled.
This function is invalid when the appliance at the Fan mode.
When it displays “LOUVER” button:
Press this button, the vertical wind direction vanes can rotate automatically. When you have
the desired horizontal wind direction, press it again, the vertical wind direction vanes will be
stopped at the situation of your choice.
b. Application method