15
then opens an omnirange angle to its closing direction. If in the course encounters starting up.
then starting up action immediately. with swing speed 22°/ s.
2. When machine is on(with remote control or button pressing). the air blade makes a
complete shutdown. then swing an omnirange angle to its opening direction. then back to
initial point. While heating. it stays at point 5( chart 3
)
.while refrigeration. then swing back to
point 2
(
chart 3
)
.
3. The flap button on remote control can set the air blade to free swing or Manual swing.
4. For free swing. the swing scope of heating is 50°.as (chart 3)3-5.for cooling, swing scope is
50°. 2-4 in chart, swing speed is 5.5°/ s.
5. When the machine is turned on. while remote control set air blade non-swing. swing angle
swings to a proper position according to different mode and fix e.g. : cooling mode is
(
chart 3
)
position 2. heating mold is
(
chart 3
)
position 5. If it's set as free swing, no matter the fan is
open or not. air blade swings within limitation. If the remote control set non-swing, air blade
will stop at the set position.
6. Turn off (by remote control or button pressing).when the inside fan motor stops working, air
blade will close by itself.
7. Press the emergency switch
to get into automatic mold, air blade works according to
cooling mode. If the system selects a certain mode, air blade runs according to the selected
mode requirement.
Swinging angle of E model air blade as follows:
1. Position of complete shutdown 2. Refrigeration position
3. Refrigerating pendulum terminal point 4. Heating pendulum terminal point
5. Heating position 6.position of complete shutdown
Swinging angle of repeating motor for H series off-set air conditioner 9000Btu and 12000Btu
Summary of Contents for GPAC12039
Page 35: ...33 ...
Page 36: ...34 Section 6 Explosion View Model e g ...
Page 38: ...36 Outdoor Unit Model e g ...
Page 43: ...41 b Single Cooling Model ...
Page 44: ...42 Section 9 Service Record Date Page Part Cause Report ...