background image

PRF

Page 2 

Installation Instructions

Contact Premier Mounts with any questions: 
(800) 368-9700
[email protected]

Contents

Warning Statements

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND 
COMPLETELY UNDERSTOOD TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP THESE 
INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.

PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY 
UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, 
DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR 
IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE 
PROPER SAFETY GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

At least two qualifi ed people should perform the assembly procedure. Personal injury and/or property damage can result 
from dropping or mishandling the fl at panel.

If mounting to wall studs, make sure that the mounting screws are anchored into the center of the wall studs. Use of an 
edge-to-edge stud fi nder is recommended.

Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are 
no electrical wires in the wall. Cutting or drilling into an electrical line may cause serious personal injury.

Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a 
water or gas line may cause severe property damage or personal injury.

This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious 
personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of 
impact.

Weight Capacity

Maximum fl at panel weight:

50lbs.

THE WALL STRUCTURE MUST BE CAPABLE OF HOLDING 
FIVE (5) TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, 
THEN THE WALL STRUCTURE MUST BE REINFORCED.

Installation Tools. ...................................................................................................................................................... 3
Parts List................................................................................................................................................................... 3
Mounting Hardware. ................................................................................................................................................. 4
Features. .................................................................................................................................................................. 5
Installing the PRF Mount. ......................................................................................................................................... 6

Single Stud Installation. ............................................................................................................................... 6
Solid Surface. .............................................................................................................................................. 7

Determining the Mounting Hardware. ....................................................................................................................... 9
Universal Spacer Installation (optional). ................................................................................................................... 9
VESA 75/100 Installation. ....................................................................................................................................... 10
Attaching the UFP-280 Adapter Plate..................................................................................................................... 11
Attaching the PRF to the Adapter Plate. ................................................................................................................. 12
Technical Specifi cations. ........................................................................................................................................ 12
Warranty. ................................................................................................................................................................ 13

Summary of Contents for PRF

Page 1: ...SA and Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 Universal Ultra Flat Mount Model PRF 9531 003 001 04 ...

Page 2: ... make sure that the mounting screws are anchored into the center of the wall studs Use of an edge to edge stud finder is recommended Be aware of the mounting environment If drilling and or cutting into the mounting surface always make sure that there are no electrical wires in the wall Cutting or drilling into an electrical line may cause serious personal injury Make sure there are no water or nat...

Page 3: ...ation hardware and components Make sure that none of these parts are missing and or damaged before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts 800 368 9700 Front Cover Plate Qty 1 Thread Depth Indicator Qty 1 PRF Mount Hardware Wall Plate Qty 1 Pencil 1 8 Wood Drill Bit Electronic Stud Finder Phillips Tip Screwdriver Tape...

Page 4: ...x 16mm Combo Screw Qty 4 M5 x 20mm Combo Screw Qty 4 M5 x 30mm Combo Screw Qty 4 M5 x 45mm Combo Screw Qty 4 M6 x 10mm Combo Screw Qty 4 M6 x 16mm Combo Screw Qty 4 M6 x 20mm Combo Screw Qty 4 M6 x 30mm Combo Screw Qty 4 M6 x 45mm Combo Screw Qty 4 M4 x 10mm Combo Screw Qty 4 M4 x 5mm Combo Screw Bagged Separately Qty 4 10 x 1 1 4 Wood Screws Qty 4 10 Wall Anchors Qty 4 M4 Flat Washer Qty 4 M5 Fla...

Page 5: ...ing Point M6 x 12mm Securing Screws Wall Plate Mounting Slot Mounting Tab Wood Stud Mount ing Point see NOTE below Power Access Opening These mounting points also act as mounting points if you decide to mount the PRF to a handibox using the 6 32 x 1 screws It is recommended that all electrical wiring be done by a licensed electrician ...

Page 6: ...ired viewing location Use a stud finder to locate one 1 wall stud closest to the viewing location Step 1 Single Stud Installation Step 2 Step 3 Wall Stud Electronic Stud finder 1 8 Drill Bit Once the stud has been located use a pencil to mark the center of the stud Drill a pilot hole at the marked location using a power drill and a 1 8 drill bit Only use 1 8 drill bit when drilling the pilot holes...

Page 7: ... secure a standard electrical handibox to the mount Secure the wall plate to the center of the wood stud by using two 2 10 x 2 wood screws Do not over tighten the mounting screws Determine the desired viewing location Solid Surface Mark Level Wall Plate Place the mount into position against the wall and level the mount Mark four outer holes used to secure the mount When determining viewing height ...

Page 8: ...plastic wall anchors aligning the mounting holes Secure the wall plate using four 4 10 x 1 1 4 mounting screws Use a screwdriver to tighten the 10 x 1 1 4 screws Step 4 S tep 2 Solid Surface 1 16 Drill Bit Mounting Hole Power Drill Drill four 4 holes using a 1 16 drill bit and power drill Insert four 4 10 plastic wall anchors into the holes that were drilled Use a hammer to gently tap the plastic ...

Page 9: ...hpick into the threaded inserts found on the back of the flat panel Use a pencil to mark the depth of the threaded insert on the small straw or toothpick Mark the straw or toothpick 1 8 above the depth of the threaded insert as shown in Figure 1 Insert the small straw or toothpick into the remaining threaded inserts to compare and verify their depth using the straw or toothpick s 1 8 allowance mar...

Page 10: ... touching the flat panel surface Do not over tighten the mounting screws Cover Plate Securing Screw Pre Installed Mounting Point Flat Panel Slotted Opening M4 x 10mm Screw If you have a recessed VESA 75mm 100mm pattern or need more spacing between the wall and the flat panel use the appropriate number of universal spacers and corresponding length mounting hardware If your mounting pattern is not 7...

Page 11: ...t head screws Using rounded combo screws for the 200mm x 100mm VESA plate may damage your flat panel Mounting Hardware Universal Spacer Adapter Plate Flat Panel 200mm x 200mm Pattern If you have a recessed mounting pattern use the universal spacers to compensate for the indentation Attach the VESA Adapter Plate to the back of the flat panel using the appropriate mounting hardware Mounting Hardware...

Page 12: ...M4 Phillips Flat Head screws only B 200 x 200 VESA Pattern If an M4 or M5 is to be used a M4 or M5 washer must be used C 100 x 100 VESA Pattern D 75 x 75 VESA Pattern Attaching the PRF to the Adapter Plate Locate the mounting points on the adapter plate Align the mounting points of the cover plate with those on the back of the flat panel Insert four 4 M4 x 5mm screws and tighten using a screwdrive...

Page 13: ...RCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOVING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO ...

Reviews: