© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 33
Figure 11: Active Status Light Conditions
On
Off
Active Status Light -
has only five states:
Off
•
No power to
the MC
Solid
Blue
•
All OK
electrically
Pulsing
Blue
•
Check
belt/deck
•
(P80) Maint.
Counter.
Solid
Yellow
•
Had error,
recovered
Pulsing
Yellow
•
Had error,
could not
recover
Motor Controller light-
The Motor Controller Light (MCL) will illuminate in one of two states:
-
Green
– MC is working correctly
-
Yellow
– A fault has occurred. The MC may be working correctly after fault reset, or the MC
may have in internal fault that will need to be corrected. Troubleshooting is required. The
MCL can only be reset to Green through the diagnostics menus.