© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 48
Error 16 - A.C. Input Voltage Too Low
MCL
– Green
ASL
– Yellow Solid
Description
The condition that causes error 16 has to persist for 15 seconds before it is logged. The most
common cause of this problem is external power fluctuations due to brownouts, blackouts or
other poor power conditions. This can also be caused by wiring that is too small of a gauge to
handle the current, or if the neutrals are shared between multiple outlets. Less likely but
possible is a worn deck and belt causing high current.
Possible Causes
1. Prolonged brown out/consecutive short blackouts/.other poor power conditions
2. Shared neutral/too small wiring/belt deck need replacement
3. Flipping power switch ON/OFF over and over again
4. Motor controller hardware issue
Possible Remedies-
1
Find out if blackouts/brownouts have occurred recently in that area
2
Check if treadmill was running off of a backup generator or backup power source
3
Ask that an electrician verify wiring
4
Monitor minimum rms line voltage with:
5
Treadmill at banner
6
Treadmill at 6MPH with runner
7
Treadmill at banner, run at 6MPH on a neighboring tread
Error (none) - Key Depressed at Power Up- No Error Code Generated
MCL
– Green
ASL
– Blue
Description
The power up test sequence has detected a key in the operated condition. The power up test
sequence is performed every time the unit is turned on (powered up) or reset. This test is
performed because a permanently stuck key will inhibit the correct operation of the unit.
Possible Causes
1. A key on the display housing is permanently stuck in the operated condition.
Summary of Contents for TRM 811.v2
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 93...
Page 105: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 106: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 106...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 107...
Page 108: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 108...
Page 109: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 109...
Page 110: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 110...