9.45, 9.45i Treadmill
Page 45
Procedure 6.6 - Replacing the Transformer (1L Units)
Removing the Transformer
1.
Remove the hood as described in Procedure 5.1 of the Residential Treadmill Service
Manual.
2.
Disconnect the wires from the transformer terminals listed in Table 6.2.
Table 6.2 - Transformer Connections
WIRE
TRANSFORMER TERMINAL
Blue wire
10
Brown wire
8
Blue wire
6
Black wire
5
Red wire
4
Black wire
2
Red wire
1
3.
Remove the screws that secure the transformer to the treadmill frame.
4.
Remove the transformer from the treadmill frame.
Replacing the Transformer
5.
Position the transformer at its mounting location.
6.
Tighten the screws that secure the transformer to the treadmill frame.
7.
Connect the wires listed in Table 6.2 to the transformer.
8.
Check the operation of the treadmill as described in Section Three of this appendix, then
replace the hood.
Summary of Contents for 9.45
Page 55: ...9 45 9 45i Treadmill Page 55 Wiring Diagram 7 1 9 45 1L Unit...
Page 56: ...9 45 9 45i Treadmill Page 56 Block Diagram 7 2 9 45 1L Units...
Page 57: ...9 45 9 45i Treadmill Page 57 Wiring Diagram 7 3 9 45 2P 3Y Units...