13
User Manual
neuro 102
Parameter Description
Settings
(Default Value)
-999 to 999
(Default : 3)
ALARM-2 TYPE
Select the Alarm-2 activation type. Selecting ‘None’ will disable
the alarm and suppress all the related parameters for Alarm-2.
ALARM-2 SETPOINT
(Available for Process High or Process Low Alarm-2 Type)
Sets Alarm limit independent of control setpoint.
ALARM-2 DEVIATION BAND
(Available for Deviation Band Alarm-2 Type)
Sets positive or negative deviation (offset) limit from control
setpoint for High or Low Alarm-2 activation, respectively.
3 to 999
(Default : 3)
ALARM-2 WINDOW BAND
(Available for Window Band Alarm-2 Type)
Sets symmetrical positive and negative deviation (offset) limits
from control setpoint for both High and Low Alarm-2 activation.
1 to 999
(Default : 2)
ALARM-2 HYSTERESIS
Sets differential (dead) band between Alarm-2 switching ON and
OFF states.
ALARM-2 INHIBIT
Set to Yes to suppress Alarm-2 activation upon power-up or
process start-up.
ALARM-1 INHIBIT
Set to Yes to suppress Alarm-1 activation upon power-up or
process start-up.
(Default : Yes)
No
Yes
(Default : None)
None
Process Low
Process High
Deviation Band
Window Band
End of Profile
Min. to Max. Range
specified for the
selected Input Type
(Default :
For Process Low : -200
For Process Low : 1300)
ALARM-2 LOGIC
(Default :
)
Direct
Reverse
Direct
Set to Yes to suppress Alarm-2 activation upon power-up or
process start-up.
(Default : Yes)
No
Yes