Chapter 2 Standard Specification
17
Items
Specifications
Speed start tracking
method
The inverter automatically tracks motor speed after it
starts
Parameter protection
function
Protect inverter parameters by setting administrator
Password and decoding
Displ
a
y
LED/OL
ED
display
keyboard
Running
information
Monitoring objects including: running frequency, set
frequency, bus voltage, output voltage, output
current, output power, output torque, input terminal
status, output terminal status, analog AI1 value,
analog AI2 value, motor Actual running speed
,
PID
set value percentage, PID feedback value percentage.
Error
message
At most save three error message, and the time, type,
voltage, current, frequency and work status can be
queried when the failure is occurred.
LED display
Display parameters
OLED display
3
Optional,
prompts
operation
content
in
Chinese/English text.
Copy parameter
3
Can upload and download function code information
of frequency converter, rapid replication parameters.
Key lock and function
selection
Lock part or all of keys, define the function scope of
some keys to prevent misuse.
Co
m
m
u
n
ic
a
tio
n
RS485
The
optional
completely
isolated
RS485
communication module can communicate with the
host computer.
En
v
ir
o
n
m
en
t
Environment
temperature
-10
℃
to 40
℃
(temperature at 40
℃
to 50
℃
,
please derating for use)
Storage temperature
-20
℃
to 65
℃
Environment
humidity
Less than 90% R.H, no condensation.
Vibration
Below 5.9m/s² (= 0.6g)
Application sites
Indoor where no sunlight or corrosive, explosive gas
and water vapor, dust, flammable gas, oil mist, water
vapor, drip or salt, etc.
Altitude
Below 1000m
Pollution degree
2
Pr
o
d
uc
t
sta
n
d
a
rd
Product adopts safety
standards.
IEC61800-5-1:2007
Product adopts EMC
standards.
IEC61800-3:2005