Chapter 5 Function parameter
100
23
PLC status reset
When PLC pauses and runs again, this terminal is
used to reset the inverter to the initial state of
simple PLC.
24
Wobbulate pause
When the inverter outputs at center frequency.
Wobbulate will pause
25
Counter input
Input terminal of the count pulse
26
Counter reset
Clear counter status
27
Length count input
Input terminal of the length count.
28
Length reset
Clear length
29
Torque control prohibited
When the inverter torque control is prohibited, the
inverter will enter speed control mode.
30
High-speed pulse input
(only valid for DI5 )
DI5 is used as pulse input terminal.
31
Reserve
Reserve
32
Immediately DC braking
If the terminal is active, the inverter switches
directly to DC braking status
33
External fault normally
closed input
When the signal of external fault normally closed
input is inputted into the inverter, the inverter will
report fault Err.15 and shutdown.
34
Frequency change enable
If the function is set to be valid, when the
frequency changes, the inverter does not respond
to frequency changes until the terminal state is
invalid.
35
PID action direction as
reverse
If the terminal is valid, PID action direction
opposites to the direction set by E2.03
36
External parking terminal
1
Under keyboard control mode, the terminal can be
used to stop the inverter, same as STOP key on the
keyboard.
37
Control command switch
terminal 2
Used to switch between terminal control and
communication control. If the command source is
selected as terminal control, the system will be
switched to the communication control mode
when the terminal is active; vice versa.
38
PID integral pause
When the terminal is active, the PID integral
adjustment function is paused, but the proportion
and differential adjustments of PID are still valid.
39
Switch
between
frequency source master
When the terminal is active, the frequency source
A is replaced by the preset frequency (F0.01)