background image

page no. 26 of 36 

    

Vision Maxi

 User Instructions  Doc Ref M609 issue 1.0 June 2021.

  

Press the 

A

 key again

Appear 

HO

 heating only .

Wait for 3 seconds without touching anything to memorise the setting.

2.15   Brightness  control

The display brightness sensor can be disabled (leaving the 
maximum brightness at all times).

To adjust the brightness of the display:

Keep the

 key pressed for 10 seconds

"ds" (disabled) or "En" (enabled) appears.

2.16   Touch screen display key lock

Press and hold the 

 button for 3 seconds

The key lock function is activated on the display.
The stand-by symbol flashes every second.

Any action is prevented by the user.

To deactivate the lock:

press the key for 3 seconds

The lock remains active also for the next operations performed via remote control and in the event of a power failure.

2.17   hotel  function

Keep the

 key pressed for 10 seconds

If the "En" function is enabled :

• the dehumidification and Auto functions are disabled

• only ventilation, heating and cooling are left on

• is reduced from 22 to 28 in cooling mode and from 16 to

24 in heating mode.

2.18   Operations after installation 

Before leaving the site, the packaging should be gathered up 
and all traces of dirt that have deposited on the unit during 
assembly should be eliminated with a damp cloth.
Once all the checks and controls on the correct operation 
of the appliance have been completed, the installer must 
explain the following to the user:

• the basic characteristics of the appliance

• the instructions for use

• the routine maintenance

Summary of Contents for Vision Maxi

Page 1: ...w w w p o w r m a t i c c o u k Doc Ref M609 Issue 1 0 June 2021 Vision Maxi Installation Servicing Manual Issue 1 0 June 2021...

Page 2: ...our behalf Conditions of Guarantee 1 The air conditioner must have been installed by a competent installer and in accordance with the manufacturer s instructions and any building regulations and local...

Page 3: ...tive and implementing regulation 206 2012 EU and Italian implementing regulation Legislative Decree no 15 of 16 02 2011 F Gas Regulation 2014 517 EU on fluorinated greenhouse gases And subsequent amen...

Page 4: ...4 2 6 Unpacking p 14 2 7 Handling without packaging p 15 2 8 Installation site p 15 2 9 Installation minimum distances p 16 2 10 Positioning p 16 2 11 Condensation drain preparation p 20 2 12 Electric...

Page 5: ...age no 5 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 5 Technical information p 32 5 1 Technical data p 32 5 2 Dimensions p 33 5 3 RED Compliance Statement p 33 5 4 Safety p 33...

Page 6: ...ammable and odourless Avoid proximity to sources of ignition in continuous operation open flames gas appliances electric stoves lighted cigarettes etc Instructions Read the instructions carefully befo...

Page 7: ...re is pressurised refrigerant gas and live electrical components inside the appliances The installation and subsequent maintenance phases must be carried out exclusively by authorised and qualified pe...

Page 8: ...to off It is forbidden to modify the safety or adjustment devices or adjust without authorization and indications of the manufacturer It is forbidden to pull unplug or twist the device s electric cabl...

Page 9: ...efore invalidates the warranty 1 8 Destination of use These appliances have been designed for conditioning and or heating rooms and they must be destined solely for this purpose in accordance with the...

Page 10: ...i lifting bracket 11 External air expulsion 12 Remote control 13 Internal exchanger 14 External fan 15 Condensation pump 16 Condensation drain valve 17 Floater 18 External exchanger 19 External air pr...

Page 11: ...L00771II Recessed formwork for corner installation with left hand exit Compatible with only DC Inverter versions All L00772II Accessories supplied separately Grilles and accessories Kit n 2 external...

Page 12: ...ut to ensure that the risk of combustion is minimised before starting work on systems containing flammable refrigerants The appliance must be protected against accidental impacts to prevent mechanical...

Page 13: ...when the load is lifted off the ground Avoid dangerous situations when using a hoist to lift the appliance During transportation the appliance must be kept in vertical position Avoid exposure to sour...

Page 14: ...e The equipment must always be handled vertically Check if there is refrigerant inside the package using an electronic leak detector suitable for the system refrigerant If it is present the refrigerat...

Page 15: ...ecessary to check carefully that the weight of the unit does not exceed the regulations in relation to the number of people used 2 8 Installation site The location of the appliance must be determined...

Page 16: ...use damage to persons or property if it should detach from its base The unit should not be installed in a position where the air flow is aimed directly at the people nearby Provide the following a nea...

Page 17: ...or models 15 HP DC Inverter B C F IN OUT D E A Hold the template in the correct position with tape Preliminary warnings The wall mounting bracket supplied as an accessory is required to position the u...

Page 18: ...xternal side The maximum length of the holes is 1 meter Curves are prohibited To prevent the creation of large quantities of dust and debris in the room it is recommended to couple the core drill to a...

Page 19: ...r so that the flaps are in vertical position insert the counterflange in the hole toward the interior of the room rotate it so that the hooks are in vertical position pull the chains so that the sprin...

Page 20: ...If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always slope towards...

Page 21: ...eakage of water The drainage pipe must be insulated for sections running inside houses in order to prevent condensate formation on its surface If needed it is possible to empty the condensation collec...

Page 22: ...e of minimum 3 mm or using a device enabling the complete disconnection of the appliance in overvoltage III category conditions Please check that the power supply is provided with suitable protections...

Page 23: ...apter Removal of aesthetic panels and grilles p 27 To access the connections unscrew the screws of the electrical panel remove the electrical panel cover Connection The appliance leaves the factory fu...

Page 24: ...the CP contact that places the device in standby and guarantees correct post ventilation GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact G R G R C P G R BL YG BR Configuration with the ne...

Page 25: ...esthetic lower cover kit Code GB0737II 2 Fixing screws supplied with the optional kit GB0737II 3 Right support bracket for the flap A B 1 3 2 180 Configuration After adjusting the air outlet flap posi...

Page 26: ...y for 3 seconds The lock remains active also for the next operations performed via remote control and in the event of a power failure 2 17 hotel function Keep the key pressed for 10 seconds If the En...

Page 27: ...9 issue 1 0 June 2021 2 19 Removal of aesthetic panels and grilles 2 1 2 20 Assembly of aesthetic panels and grilles To assemble positioning the aesthetic panel insert the two screws Screw in the two...

Page 28: ...nces electric stoves lighted cigarettes etc Smoking in the vicinity of the appliance is prohibited Using a mobile phone near the appliance is prohibited Using leak detectors with halogen lamps is proh...

Page 29: ...c panels and grilles p 27 For grid assembly operations see chapter Assembly of aesthetic panels and grilles p 27 extract the filter by lifting it remove the dust from the filter with a vacuum cleaner...

Page 30: ...m irons hot plates etc Displayed faults In the event of a malfunction the display shows an alarm code The appliance still retains some functions see the OPERATION column Alarm Cause Function E1 Faulty...

Page 31: ...rvice During heating condensation should drain freely through the specific pipe In the event of an alarm check that the condensation pipe is not bent or obstructed thus preventing the water from flowi...

Page 32: ...minimum fan speed m h 300 Aeraulic data outdoor Ventilation speed Nr 3 Air flow at the maximum fan speed m h 550 Air flow at the medium fan speed m h 460 Air flow at the minimum fan speed m h 400 Ele...

Page 33: ...ight mm 549 Total depth mm 165 Empty weight kg 41 0 Wall hole diameter mm 202 Wall holes distance mm 293 5 3 RED Compliance Statement Compliancewith2014 53 EURadioEquipmentDirective RED In accordance...

Page 34: ...page no 34 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 Notes...

Page 35: ...page no 35 of 36 Vision Maxi User Instructions Doc Ref M609 issue 1 0 June 2021 Notes...

Page 36: ...e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to c...

Reviews: