6. Specifications 

 

 

MODEL 

1.1K 

1.5K 

2K  

3K* 

CAPACITY 

1100 VA / 770 W 

1500 VA / 1050 W 

2000 VA / 1400 W 

3000 VA / 2100 W 

INPUT 

Acceptable Voltage Range 

81-134 VAC/86-139 VAC/89-145AVC/102-152 VAC 

or 162-268 VAC/162-268 VAC/170-280AVC/177-290 VAC 

Frequency Range 

60/50 Hz ±  5 Hz (auto sensing) 

OUTPUT 

Voltage Regulation (AC Mode) 

110 (-15%/+10%) /115(-14%/+10%)/120(-14%/+10%)/127(-12%/+10%) VAC 

or 208 (-10%/+16%) /220(-15%/+10%)/230(-15%/+10%)/240(-15%/+10%) VAC 

Voltage Regulation (Batt. Mode) 

110/115/120/127 VAC or 208/220/230/240 VAC ± 1.5%(before battery alarm) 

Frequency Range (Batt. Mode) 

50 Hz or 60 Hz ±  0.1 Hz 

Current Crest Ratio 

3:1 

Harmonic Distortion 

2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery 

alarm) 

Transfer Time 

Typical 2-6 ms, 10ms max.             

Waveform (Batt. Mode) 

Pure Sine Wave 

Overload 
capacity 

AC mode 

103%~120% (-5%/+10%) 5 minutes 

120%~150% (-5%/+10%) 10 sec 

>150%(-5%/+10%) 1 sec 

Battery mode 

103%~110% (-5%/+10%) 1 minutes 

110%~150% (-5%/+10%) 10 sec 

>150%(-5%/+10%) 0.5 sec 

EFFICIENCY 

AC Mode 

96% 

Buck & Boost Mode 

95% 

Battery Mode 

 88%, up to 90% @ nominal battery voltage 

BATTERY 

Battery Type & Number 

12 V/7 Ahx2 

12 V/9 Ahx2 

12 V/7 Ahx4 

12 V/9 Ahx4 

Charging Voltage 

27.4 VDC ±  1% 

54.8 VDC ±  1% 

Recharge Time 

4 hours recover to 90% capacity 

PROTECTION 

Full Protection 

Overload, short, discharge, and overcharge protection 

ALARM 

Battery Mode 

Sounding every 10 seconds 

Low Battery 

Sounding every 2 seconds 

Overload 

Sounding every second 

Battery Replacement Alarm 

Sounding every 2 seconds 

Fault 

Continuously sounding 

PHYSICAL 

Dimension, DXWXH (mm) 

397 x 145x 220 

455 x 145x 220 

Net Weight (kg) 

11.65 

12.35 

18.1 

20.3 

ENVIRONMENT 

Operating Humidity 

0-90 % RH @ 0- 40°C (non-condensing) 

Noise Level 

Less than 45dB 

MANAGEMENT 

Smart RS-232/USB 

Supports Windows®  2000/2003/XP/Vista/2008, 7/8/10, Linux, Unix, and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

* Only available for 208/220/230/240VAC system. 

Product specifications are subject to change without further notice. 

Summary of Contents for VI TW 1.1K

Page 1: ...User Manual PowerWalker VI TW Series Uninterruptible Power Supply System Version 1 0...

Page 2: ...tion And Setup 4 2 1 Rear panel view 4 2 2 Operating principle 5 2 3 Setup the UPS 5 3 Operations 7 3 1 Button operation 7 3 2 LCD Panel 7 3 3 Audible Alarm 8 3 4 LCD display wordings index 9 3 5 UPS...

Page 3: ...Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system Please use only VDE tested CE marked or UL marked for 110 115 120 127 VAC models...

Page 4: ...ries Released electrolyte is harmful to the skin and eyes It may be toxic a Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified be...

Page 5: ...tial environment this product may cause radio interference in which case the user many be required to take additional measures only for 220 230 240 VAC system Only for 110 115 120 127 VAC system NOTE...

Page 6: ...ace for future use 2 1 Rear panel view IEC Type 1 1K 1 5K 2K 3K NEMA Type 1 1K 1 5K 2K 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC...

Page 7: ...nd door Maintain minimum clearance of 100mm in the bottom of the UPS to avoid dust and high temperature 2 Maintain an ambient temperature range of 0 C to 45 C for UPS optimal operation For every 5 C a...

Page 8: ...sed a metal plate is connected to Pin 1 and Pin2 for UPS normal operation To activate EPO function remove two screws on EPO port and green connector will be removed Note The EPO function logic can be...

Page 9: ...election key Press this button to confirm selection in UPS setting mode SELECT Button Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage b...

Page 10: ...ion Indicates the load level by 0 24 25 49 50 74 and 75 100 Indicates overload Programmable outlets information Indicates that programmable management outlets are working Mode operation information In...

Page 11: ...meters to set up the UPS Parameter 1 It s for program alternatives Refer to below table Parameter 2 is the setting options or values for each program 01 Output voltage setting Interface Setting Parame...

Page 12: ...ng Interface Setting Parameter 2 Set up the charger maximum current 1 2 4 6 8 setting the maximum charger current at 1 2 4 6 8 Ampere Default 8A Note This setting is only effective for super charger 0...

Page 13: ...Selection button for 3 seconds to enter Setting mode Step 3 Press the Up button ON MUTE to switch to 02 of program list Then press Enter button to enter value setting of parameter 2 Press the Up butto...

Page 14: ...regulation range but higher than low loss point the boost AVR will be activated Battery mode When the input voltage is beyond the acceptable range or power failure UPS will backup power from battery...

Page 15: ...every 2 seconds EPO enable Sounding every 2 seconds Over temperature Sounding every 2 seconds Charger failure Sounding every 2 seconds Battery fault Sounding every 2 seconds At this time UPS is off to...

Page 16: ...nal or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 on LCD display and alarm is continuously sounding Battery voltage is too high or th...

Page 17: ...ult your dealer Batteries defect Contact your dealer to replace the battery Fault code is shown as 45 on LCD display At the same time alarm is continuously sounding The charger does not have output an...

Page 18: ...103 110 5 10 1 minutes 110 150 5 10 10 sec 150 5 10 0 5 sec EFFICIENCY AC Mode 96 Buck Boost Mode 95 Battery Mode 88 up to 90 nominal battery voltage BATTERY Battery Type Number 12 V 7 Ahx2 12 V 9 Ahx...