Table 5-2
Inspection and Corrective Action
ITEM
INSPECT FOR
CORRECTIVE ACTION
External Connector
plugs and jacks
Chassis, fan &
extruded heatsinks
External Electrical
Wiring
External Solder
Connections
Dirt and moisture
buildup
Front panel controls
and meters
Looseness, bent or corroded
contacts, damage or improper
seating in mating connector
Dirt and Corrosion
Broken, burned or pinched
wire; frayed, worn or missing
insulation
Corrosion, loose, cracked, or
dirty connections
Short circuits, arcing, corrosion,
overheating
Dirt and corrosion
Clean contacts with solvent
moistened cloth, soft bristle brush,
small vacuum or low compressed
air.
Replace connectors damaged,
deeply corroded, or improperly
seated in mating connector.
Clean with cloth moistened with
soapy water.
Repair or replace defective wires.
Clean and resolder connections.
Clean as required.
Clean with cloth moistened with
soapy water.
Use a Kimwipe tissue and GTC
glass cleaning compound to clean
the meter faces.
M550001-01