Table 3-3
D-Shell Connector J1 Designations and functions – Continued
J1
DESIGNATOR
SCHEMATIC
SYMBOL
FUNCTIONAL
DESCRIPTION
15
16
17
18
19
20
21
22
23
24
25
VP
10V
IP
10V
FAULT
S/D
FAULT
V
MON
VP
RTN
VP
RES
IP
RES
IP
RTN
COM
IP
RTN
Remote voltage programming using a 0-10 VDC source.
Remote current programming using a 0-10 VDC source.
Fault state. A high state indicates a converter,
temperature or bias supply fault, and the LED on the front
panel will illuminate.
Shutdown fault. This terminal goes to high state in the
event of converter, temperature, overvoltage or bias
supply fault.
Output voltage monitor. 0-10 VDC equals to 0-100%
rated voltage.
Voltage programming return. Used with J1-9, J1-15 or
J1-21 and must be referenced to or within ±3V of the
circuit common.
1 milliamp current source for remote voltage
programming using resistance. 0-5k ohm resistor
referenced to common will program the output voltage
from 0-100%.
1 milliamp current source for remote current programming
using resistance. 0-5k ohm resistor referenced to
common will program the output from 0-100%.
Current programming return. Used with J1-10, J1-16 or
J1-22 and must be referenced to or within ±3V of the
circuit common.
Circuit common.
Current programming return. Used with J1-10, J1-16 or
J1-22 for remote current programming and must be
referenced to or within ±3V of the circuit common.
Note: This interface is not usable on units equipped with digital programming
functionality, i.e., the “R” and “S” series models.
M550001-01
3-4
Summary of Contents for D3 Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 28: ...This page intentionally left blank M550001 01 2 12 ...
Page 44: ...This page intentionally left blank M550001 01 3 16 ...
Page 59: ...Figure 4 4 P83 P86 Internal Layout M550001 01 4 15 ...
Page 60: ...Figure 4 5 P83 P86 Converter Card M550001 01 4 16 ...
Page 61: ...Figure 4 6 P63 P66 Converter Card M550001 01 4 17 ...
Page 62: ...This page intentionally left blank M550001 01 4 18 ...