Appendix B - Measurement Specifications
83
0.2Hz to 200Hz range
0.1% + 0.005A + 0.01%/Hz
add 0.05% below 0.4Hz if AC coupled
add 0.02A for peak measurements
2Hz to 2KHz range
0.1% + 0.005A + 0.001%/Hz
add 0.05% below 4Hz if AC coupled
add 0.02A for peak measurements
20Hz to 5KHz range
0.1% + 0.005A + 0.4%/KHz
add 0.05% below 40Hz if AC coupled
add 0.04A for peak measurements
20Hz to 75KHz range
below 10KHz : 0.1% + 0.01A + 0.4%/KHz
10KHz to 40KHz : 0.03A + 0.4%/KHz
above 40KHz : 16% + 0.03A
add 0.1% below 40Hz if AC coupled
add 0.1A for peak measurements
Common Mode
0.000001A / V / KHz (i.e. 0.0002A per KHz at
230V)
Current to Current Crosstalk
>80dB decreasing linearly to >50dB at 75KHz
Phase (to other phase)
0.1° + 0.05°/KHz
Phase (to Voltage)
0.1° + 0.05°/KHz
add 1° for frequencies 1KHz to 10KHz
Internal Current (Option 40A)
DC
0.1% + 0.025A
0.02Hz to 20Hz range
0.1% + 0.025A + 0.1%/Hz
add 0.15% below 0.04Hz if AC coupled
add 0.1A for peak measurements
0.2Hz to 200Hz range
0.1% + 0.025A + 0.01%/Hz
add 0.05% below 0.4Hz if AC coupled
add 0.1A for peak measurements
2Hz to 2KHz range
0.1% + 0.025A + 0.001%/Hz
add 0.05% below 4Hz if AC coupled
add 0.1A for peak measurements
20Hz to 5KHz range
0.1% + 0.025A + 0.4%/KHz
add 0.05% below 40Hz if AC coupled
add 0.2A for peak measurements