WIRES SIZING
The voltage drop calculations are based on the wire length indicated on top of the table (both positive and negative wires of the same
length).
WIRE LENGTH < 5 FEET
MODEL
1524-2024
2524-3024
3624-4024
1512-1812
2512-3012
WIRE GAUGE
AWG 2
AWG 1/0
AWG 2/0
AWG 1/0
AWG 2/0
MAX VOLT DROP
0.207
0.217
0.229
0.260
0.340
NOM. VOLT DROP
0.138
0.145
0.153
0.174
0.229
WIRE LENGTH < 10 FEET
MODEL
1524-2024
2524-3024
3524-4024
1512-2012
2512-3012
WIRE GAUGE
AWG 2/0
AWG 3/0
AWG 4/0
AWG 3/0
AWG 4/0
MAX VOLT DROP
0.206
0.273
0.288
0.330
0.430
NOM. VOLT DROP
0.137
0.182
0.192
0.218
0.288
WIRE LENGTH < 20 FEET
MODEL
1524-2024
2524-3024
3524-4024
1512-2012
2512-3012
WIRE GAUGE
AWG 2/0
AWG 3/0
AWG 4/0
AWG 3/0
AWG 4/0
MAX VOLT DROP
0.412
0.545
0.576
0.300
0.430
NOM. VOLT DROP
0.275
0.364
0.384
0.218
0.288