The relationship between solar charging and mains charging:
Solar charging
current
Mains charging current (* maximum set charging
current)
40A
0%
30A
20%
20A
40%
10A
60%
5A
80%
0
100%
PA
: Lower voltage setting on Battery Priority
mode:
10.5V default, (single section: 10.5V, 10.6V,
10.7V, 10.8V, 10.9V, 11.0V, 11.1V, 11.2V, 11.3V,
11.5V)
PB
: Higher voltage setting on Battery Priority mode
on battery priority mode, the battery voltage is
restored and the inverter switches from city power
to Inverting mod. 13.2V default, (single battery:
13.2V, 13.3V, 13.4V, 13.5V, 13.7V, 13.9V, 14.1V,
14.4V)
PC
:, mains charges or not:
If ON AC charge, if OFF AC does not charge, AUT
the total current is given by the internal MPPT
Charger plus the AC charger when working on solar
priority mode or mains priority mode, the mains will
charge when the solar charging current is small. The
specific charging method is as follows: