Group 002
Fuels, Lubricants and Coolant
01
002
1
OURGP11,000018C
–19–12FEB04–1/1
Diesel Fuel
Consult your local fuel distributor for properties of the
diesel fuel available in your area.
In general, diesel fuels are blended to satisfy the low
temperature requirements of the geographical area in
which they are marketed.
Diesel fuels specified to EN 590 or ASTM D975 are
recommended.
In all cases, the fuel shall meet the following
properties:
Cetane number of 45 minimum. Cetane number
greater than 50 is preferred, especially for
temperatures below -20
°
C (-4
°
F) or elevations above
1500 m (5000 ft).
Cold Filter Plugging Point (CFPP) below the
expected low temperature OR Cloud Point at least
5
°
C (9
°
F) below the expected low temperature.
Fuel lubricity should pass a minimum of 3100 gram
load level as measured by the BOCLE scuffing test.
Sulfur content:
•
Sulfur content should not exceed 0.5%. Sulfur
content less than 0.05% is preferred.
•
If diesel fuel with sulfur content greater than 0.5%
sulfur content is used, reduce the service interval for
engine oil and filter by 50%.
•
DO NOT use diesel fuel with sulfur content greater
than 1.0%.
Bio-diesel fuels may be used ONLY if the fuel
properties meet DIN 51606 or equivalent specification.
DO NOT mix used engine oil or any other type of
lubricant with diesel fuel.
CTM100 (06APR04)
01-002-1
P
OWER
T
ECH
10.5 L & 12.5 L Diesel Engines
040604
PN=31
Summary of Contents for 6105ADW
Page 16: ...Contents 01 CTM100 06APR04 01 2 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 2 ...
Page 50: ...Contents 02 CTM100 06APR04 02 4 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 4 ...
Page 334: ...Contents 03 CTM100 06APR04 03 2 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 2 ...
Page 350: ...Contents 04 CTM100 06APR04 04 2 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 2 ...
Page 376: ...Contents 05 CTM100 06APR04 05 2 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 2 ...
Page 412: ...Contents 06 CTM100 06APR04 06 2 POWERTECH 10 5 L 12 5 L Diesel Engines 040604 PN 2 ...