20
Owner’s Manual for Portable Generator
Service Spark Plug
To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. See
. Inspect electrode gap with
feeler gauge and reset spark plug gap to
0.028 - 0.031 in (0.70 - 0.80 mm).
Figure 4-4. Spark Plug
NOTE:
Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Battery Replacement (if
applicable)
NOTE:
The battery shipped with the generator
has been fully charged. A battery may lose
some charge when not in use for prolonged
periods of time. If battery is unable to crank
engine, plug in the 12V charger included in the
accessory box (see the Charging a Battery
section).
IMPORTANT NOTE: Running the generator
does not charge battery.
1. See
. Disconnect battery quick
connect (C).
Figure 4-5. Battery Quick Connect
2. See
. Disconnect negative (-)
battery terminal FIRST (B).
3. Disconnect positive (+) battery terminal
SECOND (A).
Figure 4-6. Battery Cable Connection
4. Install new battery. Install hold down
bracket and tighten.
5. Connect positive (+) battery terminal (red
wire) FIRST (A). Slide rubber boot over
connection hardware.
6. Connect negative (-) battery terminal (B)
SECOND.
7. Slide rubber boot over connection hard
-
ware.
Inspect Muffler and Spark
Arrester
NOTE:
It is a violation of California Public
Resource Code, Section 4442, to use or oper
-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrester, as defined in Section 4442, main
-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for exhaust system installed on this
engine.
NOTE:
Use ONLY original equipment replace
-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
000211
(000130)
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
WARNING
WARNING
(000228)
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death, or serious injury.
C
009636
B
A
009917
Summary of Contents for PM3800
Page 26: ...24 Owner s Manual for Portable Generator Wiring Diagrams PM3800 CSA 010937...
Page 27: ...Owner s Manual for Portable Generator 25 PM4400E CSA 010938...
Page 28: ...26 Owner s Manual for Portable Generator PM4500 CSA 010939...
Page 29: ...Owner s Manual for Portable Generator 27 Notes...
Page 30: ...28 Owner s Manual for Portable Generator...
Page 31: ......
Page 61: ...Manual del usuario del generador port til 27 Diagramas de cableado PM3800 CSA 010937...
Page 62: ...28 Manual del usuario del generador port til PM4400E CSA 010938...
Page 63: ...Manual del usuario del generador port til 29 PM4500 CSA 010939...
Page 93: ...Manuel du propri taire du g n rateur portatif 27 Sch mas de c blage PM3800 CSA 010937...
Page 94: ...28 Manuel du propri taire du g n rateur portatif PM4400E CSA 010938...
Page 95: ...Manuel du propri taire du g n rateur portatif 29 PM4500 CSA 010939...