Owner’s Manual for Portable Generator
Figure 2-8. 120 VAC, 20 Amp, GFCI Duplex
Receptacle NEMA 5-20R
120 VAC, 30 Amp Receptacle (if
equipped)
Use a NEMA L5-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 3-
wire cord set to the plug and to desired load.
The cord set should be rated for 125 Volts AC
at 30 Amps (or greater). See
.
Use this receptacle to operate 120 Volt AC,
60Hz, single phase loads requiring up to 3600
watts (3.6kW) of power at 30 Amps. The outlet
is protected by a 30 Amp circuit breaker.
Figure 2-9. 120 VAC, 30 Amp Receptacle
NEMA L5-30
COsense®
Carbon Monoxide (CO) Detection
and Shut-off System (if equipped)
The COsense module monitors for the accu
-
mulation of poisonous CO gas found in engine
exhaust when the generator is running. If
COsense detects increasing levels of CO gas,
it automatically shuts off the engine. COsense
only monitors when the engine is running.
Generators are intended to be used outdoors,
far from occupied buildings and the exhaust
pointed away from personnel and buildings.
However, if mis-used and operated in a loca
-
tion that results in the accumulation of CO, like
indoors or in a partially enclosed area,
COsense shuts off the engine, notifies the
user of what has happened and directs the
user to read the instruction action label for
. COsense is not
a substitute for an indoor carbon monoxide
alarm.
See
. As the user approaches the
generator to investigate a shut-off, a blinking
RED light in the COsense badge on the side
of the generator provides notification that the
generator was shut off due to an accumulating
CO hazard. The RED light will blink for at least
five minutes after a CO shut-off. Move the
generator to an open, outdoor area and point
the exhaust away from people and occupied
buildings. Once relocated to a safe area, the
generator can be restarted and the proper
electrical connections made to supply electri
-
cal power. The RED light will stop blinking
automatically upon engine re-start. Introduce
fresh air and ventilate the location where the
generator had shut down.
See
. If a COsense system fault
has occurred and no longer provides protec
-
tion, the portable generator is shut off auto
-
matically and the YELLOW light will blink for at
least five minutes in the COsense badge to
notify the user of the fault. The COsense mod
-
ule can only be diagnosed and repaired by a
trained technician at the dealer. The generator
can be re-started, but may continue to shut-
off.
COsense will detect the accumulation of Car
-
bon Monoxide from other fuel burning sources
such as engine powered tools or propane
heaters used in the area of operation. For
example, if another generator is used and the
exhaust is pointed at a COsense equipped
generator, COsense may initiate a shut-off
due to rising CO levels. This is not an error.
Hazardous Carbon Monoxide has been
detected. The user must take action to move
and re-direct these devices to better dissipate
Carbon Monoxide far away from personnel
and occupied buildings.
000203
000844
Summary of Contents for PM3800
Page 26: ...24 Owner s Manual for Portable Generator Wiring Diagrams PM3800 CSA 010937...
Page 27: ...Owner s Manual for Portable Generator 25 PM4400E CSA 010938...
Page 28: ...26 Owner s Manual for Portable Generator PM4500 CSA 010939...
Page 29: ...Owner s Manual for Portable Generator 27 Notes...
Page 30: ...28 Owner s Manual for Portable Generator...
Page 31: ......
Page 61: ...Manual del usuario del generador port til 27 Diagramas de cableado PM3800 CSA 010937...
Page 62: ...28 Manual del usuario del generador port til PM4400E CSA 010938...
Page 63: ...Manual del usuario del generador port til 29 PM4500 CSA 010939...
Page 93: ...Manuel du propri taire du g n rateur portatif 27 Sch mas de c blage PM3800 CSA 010937...
Page 94: ...28 Manuel du propri taire du g n rateur portatif PM4400E CSA 010938...
Page 95: ...Manuel du propri taire du g n rateur portatif 29 PM4500 CSA 010939...