background image

 

26 

HV Model 

OUTPUT POWER 

5000 VA 

6000 VA 

8000VA 

10000VA  12000VA 

Connection Input 

Hardwired  Hardwired Hardwired Hardwired Hardwired

Connection Output 

Hardwired  Hardwired Hardwired Hardwired Hardwired

Battery type 

Lead-acid 
7.2 

Ah/12V 

Lead-acid 
7.2 

Ah/12V 

Lead-acid
7.2 

Ah/12V 

Lead-acid
9 Ah/12V

Lead-acid
5 Ah/12V

Number of batteries 

20 

20 

20 

20 

40 

Backup time/full load 7 min 

6 min 

5 min 

6 min 

6min 

Recharge time 

<8 hours 

to 90% 

<8 hours 

to 90% 

<8 hours to 

90% 

<8 hours 

to 90% 

<8 hours 

to 90% 

Without 

ISOTR 

280x580x570 280x580x570 257*690*700 257*690*700 257*690*700

Dimensions 
W*D*H mm With 

ISOTR 

257*590*700 257*590*700 342*690*700 342*690*700 342*690*700

Without 

ISOTR 

86 86 112 112  134 

Weight kg 

With 

ISOTR 

123 123 178  178 200 

 

 

27

Terminal Block

 

5/6K TB                                                    5/6K-ISO TB 

 
 
 
 
 
 
 
 

5/6K-ISO TB 

 
 
 
 
 
 
 
 
                                8/10/12K TB                                              8/10/12K-3

Ø TB 

 

 

 

 

 

 

 

 

8/10/12K-ISO TB                                                8/10/12K-ISO-3

Ø TB 

 
 
 
 
 
 
 

Summary of Contents for 12K VA

Page 1: ...fluenced by harmful interference from the equipment it is recommended to use one of the following preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater...

Page 2: ...servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals...

Page 3: ...nstallation must be carried out in accordance with this manual Electrical installations must also carefully follow local legislation and regulations Only qualified personnel should conduct these insta...

Page 4: ...management system always monitors the conditions of the batteries sends any forewarnings if replacement is needed Otherwise every 30 days of normal mode operation a battery discharge test is performed...

Page 5: ...in this manual The greatest care possible must be taken for any of these operations and any change thereof may prove very hazardous to the operator 5 4 Storage 4 1 Storage Please adhere to the followi...

Page 6: ...ptions Avoid extremes of temperature and humidity Maximal battery life can be attained with a recommended temperature range of 15 C to 25 C Provide protection for the equipment from moisture Space and...

Page 7: ...8 5K 6KVA Rear panel With ISO 9 8K 12KVA Rear panel Without ISO...

Page 8: ...the installation site has all electrical connections properly carried out In addition refer to figures 2 and 3 to check the fuse and cable dimensions Isolate and secure the source against reclosing Bo...

Page 9: ...ters to select Default settings are as follows Settings Selection Factory default Output Voltage Setting 208 220 230 240 Vac 230V FOR HV series Input Bypass Voltage 10 10 15 15 20 10 15 Input Frequenc...

Page 10: ...RI Output 8 24 VDC Power Fig 5 Caution Max rated values 24Vdc 50mA 15 USB port option Connecting the UPS to your computer is accomplished through the USB port on the back of your computer USB complian...

Page 11: ...Push the ENTER button to confirm and enable your function f If no pressing within 10 seconds it will return to original status 4 ENTER button Use this button to enter enable or confirm the function t...

Page 12: ...CPU Version 19 UPS configurations 1 Various settings that have been chosen are shown in the UPS setting display 2 To enter configuration mode press the FUNC button for one second The first configurati...

Page 13: ...ed For UPS to predict Backup time 0 only internal batteries 1 one external cabinet 2 two external cabinets 0 Site wiring alarm Sit Fault Set You can enable or disable the site wiring alarm Enable Disa...

Page 14: ...ps The UPS is doing a battery test No action needed The UPS will return to normal operation when it successfully completes the battery test Over Charge Constant beep Batteries are overcharged Turn off...

Page 15: ...al and workmanship for a period of 24 months from its original date of purchase 25 10 Technical Specifications GENERAL Rated power 5000VA 6000 VA 8000 VA 10000 VA 12000VA at p f 0 7 Technology On line...

Page 16: ...mber of batteries 20 20 20 20 40 Backup time full load 7 min 6 min 5 min 6 min 6min Recharge time 8 hours to 90 8 hours to 90 8 hours to 90 8 hours to 90 8 hours to 90 Without ISOTR 280x580x570 280x58...

Page 17: ...28 MAINTENANCE SWITCH NORMAL BY PASS 1 2 INV MAIN INV MAIN or...