IMPORTANT SAFETY INSTRUCTIONS

 

SAVE THESE INSTRUCTIONS

 

 

WARNING  (SAVE  THESE  INSTRUCTIONS): 

This  manual  contains  important 

instructions that should be followed during installation and maintenance of the UPS 

and batteries. The equipment can be operated by any individuals with no previous 

experience. 

 

WARNING

:  It  is  highly  recommended  to  install  the  product  in  a  controlled 

environment; maximum ambient temperature is 40°C. 

 

CAUTION (UPS has internal batteries)

: Risk of electric shock – Hazardous live parts 

inside this unit is energized from the battery supply even when the input AC power is 

disconnected. 

 

CAUTION (No user serviceable parts)

: Risk of electric shock – do not remove cover, 

no user serviceable parts inside. Refer service to qualified service personnel. 

 

WARNING (Fuses)

: To reduce risk of fire, replace only with the same type and rating 

of fuse. 

 

WARNING

: Do not disconnect battery connector under load. 

 

ATTENTION

:

 

Hazardous through electrical shock. Also with disconnection of this unit 

from the mains, hazardous voltage  still  may be accessible through supply from the 

batteries.  The  battery  supply  should  therefore  be  disconnected  in  the  positive  and 

the  negative  pole  when  maintenance  or  service  work  inside  the  battery  cabinet  or 

UPS is considered. 

 

CAUTION (For any pluggable only)

: With the installation of this equipment it should 

be  prevented,  that  the  sum  of  the  leakage  current  of  the  UPS  and  connected 

consumer does not exceed 3.5 mA. 

 

CAUTION  (For  permanent  connection  only)

:  HIGH  LEAKAGE  CURRENT,  Earth 

connection essential before connection supply. 

 

CAUTION

: Do not dispose of batteries to fire, the battery may explode. 

 

CAUTION

:  Do  not  open  or  mutilate  the  battery,  released  electrolyte  is  harmful  to 

human skin, eyes, etc. 

 

CAUTION

: A battery can bring risk of electric shock and high short circuit current.   

The following precaution should be observed when working on batteries: 

A.

 

Remove watches, rings or other metal objects. 

B.

 

Use only tools with insulated handles. 

C.

 

Wear rubber gloves and boots. 

D.

 

Do not lay tools or metal parts on top of batteries. 

E.

 

Disconnect  charging  source  prior  to  connecting  or  disconnecting  battery 

terminals. 

Servicing  of  batteries  should  be  performed  or  supervised  by  personnel  with 

knowledge of batteries and the required precautions. Keep unauthorized personnel 

away from batteries. 

 

CAUTION

:  When  replacing  batteries,  replace  with  the  same  type  and  number  of 

batteries. 

 

CAUTION

: To reduce risk of fire, use only No.26 AWG or larger telecommunication 

line cable. 

 

CAUTION

: Do not apply for uses in a computer room as defined in the Standard for 

the Protection of Electronic Computer / Data Processing Equipment, ANSI/NFPA75. 

 

CAUTION:

 

This  UPS  is  not  applicable  for  motors,  hair  dryers,  speakers,  and 

fluorescent lamps.

 

 

User’s operations: 

The only operations that users are permitted to do are: 

• 

Turning the UPS unit on and off. 

• 

Operating the users interface. 

• 

Connecting data interface cables. 

All  such  operations  are  to  be  performed  exactly  as  instructed  in  this  manual.  The 

greatest  care  possible  must  be  taken  for  any  of  these  operations  and  any  change 

thereof may prove very hazardous to the operator. 

The instructions contained within this safety manual are deemed important and should 

be closely followed at all times during installation and follow-up maintenance of the UPS 

and batteries. 

Summary of Contents for 1025VA

Page 1: ...U P S Line Interactive Simulated Sine Wave 1025VA 3000VA USER S MANUAL...

Page 2: ...S to Computer with USB RS232 port 6 6 Operations 7 6 1 Switch on with Green Mode Function 7 6 2 Switch on with Disabled Green Mode Function 7 6 3 Switch off UPS 7 6 4 Silence Function 7 6 5 Self test...

Page 3: ...n essential before connection supply CAUTION Do not dispose of batteries to fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to human skin eyes...

Page 4: ...oprocessor control This means that it operates with the newest technology high performance and powerful function The line interactive UPS is an intelligent protector and provides pure reliable AC powe...

Page 5: ...of 15 C to 25 C Only a technician from the manufacturer or an authorized agent may service the unit Do not open UPS cabinet as the components may contain high voltage and may be fatal The output rece...

Page 6: ...P mode indicator Yellow The indicator illuminates when the power is supplied from the battery AVR BUCK mode indicator Yellow The indicator illuminates when the UPS buck the input power to associate th...

Page 7: ...e connected loads exceed the protected receptacle s capacity UPS SURGE PROTECTED OUTLETS When utility power is normal the UPS outlets are powered by utility power with AVR function Any higher or lower...

Page 8: ...witch off UPS Press the OFF button at LINE or BACKUP modes and keep pressing more than 3 second to turn off the UPS ATTENTION UPS can automatically charge itself under OFF mode Advanced Battery Manage...

Page 9: ...teries ELECTRIC ENERGY HAZARD Do not attempt to rewire alter or change any battery wiring or connectors Attempting to make such alterations can cause injury 8 Trouble Shooting 8 1 BACKUP slow alarm Wh...

Page 10: ...n to the input utility power Check the connection between UPS input outlet and utility power Fuse melted or circuit breaker tripped Replace fuse or reset circuit breaker you can find a spare fuse for...

Page 11: ...2V 9Ah Quantity 2 2 3 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model LCD Control Panel IMD model Communication Port USB B type AP model Physical Dime...

Reviews: