background image

10 

©

 All rights reserved. All trademarks are property of their respective owners.

 

 

9.

 

Technical Specifications 

 

 

Model 

1025VA 

1200VA 

1500VA 

2000VA 

3000VA 

Capacity (Watts) 

615W 

720W 

900W 

1200W 

1800W 

Form 

Tower Type 

Input 

Voltage 

100 / 110 / 120 VAC or 220 / 230 / 240 VAC 

Input Voltage Range 

75 - 150 or 165 - 300 VAC 

Input Frequency Range 

50 Hz / 60 Hz (Auto Sensing) 

Output 

Waveform 

Simulated Sine Wave 

Voltage 

100 / 110 / 120 VAC or 220 / 230 / 240 VAC 

Frequency 

50 Hz / 60 Hz ± 0.5 Hz 

Transfer Time 

2 - 4 ms (Typical) 

Protection 

Full Protection 

Overload, Surge, Short Circuit 

Tele Communication 

RJ11 / RJ45 : AP model 

Battery 

Type 

12V 7.2Ah 

12V 9Ah  12V 9Ah 

Quantity 

Typical Recharge Time 

6-8 hr to 90% 

Management & Communication 

Indicator 

LED Control Panel : IMP model 

LCD Control Panel : IMD model 

Communication Port 

USB B type : AP model 

Physical 

Dimensions (mm) 

130 x 382 x 200 

130 x 440 

x 200 

Weight (kgs) 

13.5 

13.5 

16 

16.6 

22 

Shipping Dimensions (mm) 

253 x 488 x 321 

253 x 556 

x 321 

Shipping Weight (kgs) 

15.5 

15.5 

18 

18.6 

24 

Alarm 

Overload / Fault 

Continuous Beeping 

Battery Mode 

Beep every 2 seconds 

Low Battery 

Beep every 0.5 second 

Environment 

Operating Humidity 

0-90 % RH at 0-40°C (Non-condensing) 

Audible Noise 

Less then 40 dB 

* Digital Type Series are same specifications with LED Type Series, but in Digital Indicator. 

** Specifications are subject to change without further notice. 

** Specifications are for reference, actual information should be based on real product. 

Summary of Contents for 1025VA

Page 1: ...U P S Line Interactive Simulated Sine Wave 1025VA 3000VA USER S MANUAL...

Page 2: ...S to Computer with USB RS232 port 6 6 Operations 7 6 1 Switch on with Green Mode Function 7 6 2 Switch on with Disabled Green Mode Function 7 6 3 Switch off UPS 7 6 4 Silence Function 7 6 5 Self test...

Page 3: ...n essential before connection supply CAUTION Do not dispose of batteries to fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to human skin eyes...

Page 4: ...oprocessor control This means that it operates with the newest technology high performance and powerful function The line interactive UPS is an intelligent protector and provides pure reliable AC powe...

Page 5: ...of 15 C to 25 C Only a technician from the manufacturer or an authorized agent may service the unit Do not open UPS cabinet as the components may contain high voltage and may be fatal The output rece...

Page 6: ...P mode indicator Yellow The indicator illuminates when the power is supplied from the battery AVR BUCK mode indicator Yellow The indicator illuminates when the UPS buck the input power to associate th...

Page 7: ...e connected loads exceed the protected receptacle s capacity UPS SURGE PROTECTED OUTLETS When utility power is normal the UPS outlets are powered by utility power with AVR function Any higher or lower...

Page 8: ...witch off UPS Press the OFF button at LINE or BACKUP modes and keep pressing more than 3 second to turn off the UPS ATTENTION UPS can automatically charge itself under OFF mode Advanced Battery Manage...

Page 9: ...teries ELECTRIC ENERGY HAZARD Do not attempt to rewire alter or change any battery wiring or connectors Attempting to make such alterations can cause injury 8 Trouble Shooting 8 1 BACKUP slow alarm Wh...

Page 10: ...n to the input utility power Check the connection between UPS input outlet and utility power Fuse melted or circuit breaker tripped Replace fuse or reset circuit breaker you can find a spare fuse for...

Page 11: ...2V 9Ah Quantity 2 2 3 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model LCD Control Panel IMD model Communication Port USB B type AP model Physical Dime...

Reviews: