Page 21
NOTE:
DO NOT connect two red leads or two black leads
into the same generator.
4. Lift the parallel outlet cover on both generators.
Plug the black and red parallel cable leads to the
black parallel ports on each corresponding
generator control panel. Connect the yellow/green
leads to the ground terminal on each generator
and tighten the nut.
5. Start one of the generators and wait until the
OUTPUT READY INDICATOR LED illuminates.
6. Start the second generator and wait until the
OUTPUT READY INDICATOR LED illuminates
before connecting a load.
7. Plug in and turn on the desired 120 AC, single
phase, 60Hz electrical loads. It is better to attach
the item with largest load first. The total power of
4000W may be drawn from L5-30R (30A-120V)
outlet.
Always unplug all loads before stopping the
generators.
Generator
1
2
Black
Outlet
Black Cable
Red Cable
Yellow/Green Cable
Red
Outlet
Black
Outlet
Red
Outlet
Ground
Terminal
Ground
Terminal
Generator
1. Align the two inverters on a firm, flat and level
surface at a minimum 20 inch apart.
2. Both generators to be turned off and all electrical
loads disconnected before paralleling operation.
Set up and Operation
3. Make sure the LOW IDLE switch is in the OFF
position on both generators.
WARNING
If not spaced apart, the exhaust heat
from one generator discolors or melt
the plastic shell on other generator.
20”
Summary of Contents for SUA2700iD
Page 30: ...Page 28 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA2700iD ...
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 40: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 72: ...Página 30 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LISTA DE PIEZAS SUA2700iD ...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 82: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 114: ...Page 30 SCHÉMA DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES SUA2700iD ...
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 124: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...