Page 19
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1.
DO NOT
try to restart the engine.
2. Contact an Authorized Service Dealer.
3.
DO NOT
operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist.
DO NOT
try to restart
the engine.
3. Contact Customer Service.
4.
DO NOT
operate engine until oil level is corrected.
NOTE:
DO NOT
stop the engine by moving choke control to
“
START
” position.
Always ensure that the propane/LPG cylinder fully
closed when the engine is not in use. If the engine
will not be used for a period of two weeks or longer,
please see the Storage section for proper engine and
fuel storage.
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
WARNING
Do Not Overload Generator
Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and to
connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
3. Close the fuel sources.
Turn the propane/LPG cylinder knob to close
position.
Changing Fuels
DANGER
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
DANGER
DO NOT
add gasoline to the gasoline tank or connect
the Propane/LPG hose to the generator while the
generator is running.
1.Disconnect all electrical loads from the generator.
Summary of Contents for SUA2700iD
Page 30: ...Page 28 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA2700iD ...
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 40: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 72: ...Página 30 DIAGRAMA DE PIEZAS DIAGRAMA DE PIEZAS Y LISTA DE PIEZAS SUA2700iD ...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 82: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 114: ...Page 30 SCHÉMA DES PIÈCES SCHÉMA DES PIÈCES ET LISTE DES PIÈCES SUA2700iD ...
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 124: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...