General Safety Information

Model Number     

MFG Date

AMPS        

         VOLTAGE     

PHASE    

60 Hz        HP    

877-24 PUMPS

www.powerflopumps.com

   US

® Power-Flo  is a registered trademark of Power-Flo Technologies Inc.
Other brand and product names are trademarks or registered trademarks of their respective holders.
Alteration Rights Reserved.  6/09, 8/09, 9/09, 11/09

IMPORTANT!

Prior to installation, record Model Number, MFG Date, Amps, Voltage, 
Phase and HP, from pump name plate for future reference. Also record the 
Voltage and Current Readings at Startup:

Before installation, read the following 
instructions carefully. Failure to follow 
instruction and Safety information 
could cause serious bodily injury, 
death and/or property damage. Each 
Power-Flo pump is individually factory 
tested to insure proper performance. 
Closely following these instructions will 
eliminate potential operating problems, 
assuring years of trouble-free service.

 ALL RETURNED 
 PRODUCTS MUST BE
 CLEANED, 
 SANITIZED, OR  
 RECONTAMINATED 
PRIOR TO SHIPMENT, 

TO INSURE EMPLOYEES WILL NOT 
BE EXPOSED TO HEALTH HAZARDS 
IN HANDLING SAID MATERIAL. 
ALL APPLICABLE LAWS AND 
REGULATIONS SHALL APPLY

.

DO

 

NOT

  introduced into any sewer, 

either directly, or through a kitchen 
waste disposal unit or toilet:  

Seafood 

Shells, Aquarium Gravel,  Cat Litter, 
Plastic Objects (toys, utensils, etc.),  
Sanitary Napkins or Tampons,  Diapers, 
Rags, Disposable Wipes or Cloth, 
Medications, Flammable  Material, Oil or 
Grease, Strong Chemicals,  Gasoline

.

• Risk of electric shock.  To reduce risk of
  electric shock, always disconnect pump
  from power source before handling. 
  Lock out power & tag.

• Installation must be in accordance
  with the National Electric Code and all 
  applicable state and local codes.

• Installation and servicing is to be 
  conducted by qualifi ed personnel.

• These pumps are NOT to be installed 
  in locations classifi ed as hazardous in 
  accordance with the National Electric 
  Code, ANSI/NFPA 70.

• Keep clear of suction and discharge 
  openings.  Do not insert fi ngers in 
  pump with power connected.

• Always wear eye protection when 
  working on pumps.

• 

DO NOT

 use power cord to lift pump.  

  Protect cable from cuts and punctures. 
  Do not handle power cable with wet 
  hands.

• Do not us these pumps in water over 
  145˚F.  Consult Power-Flo for high 
  temperature pump models.

• Pumps build up heat and pressure 
  during operation-allow time for pumps
  to cool before handling or servicing.  

 This pump is 

NOT

 intended for 

 use in swimming pools or any 
 body of water with human 
 contact.  Pumps when used as a
 decorative water fountain 
 pump 

MUST

 be used  in circuit 

 protected by a Ground Fault 
 Interrupter.

• Bronze/brass fi tted pumps may contain
  levels higher than considered safe for 
  potable water systems. Government 
  agencies have determined that leaded 
  copper alloys should not be used in 
  potable water applications.

PFGPC- 2HP 

 

 

  

 

              

        Submersible Grinder Pumps

BACK TO INDEX

Summary of Contents for PFGPC2002HH Series

Page 1: ...TALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFGPC2002HVS HHS PFGPC2002HVSA HHSA PFGPC2022HVS HHS PFGPC2022HVSA HHSA Single Seal 2 HP 3450 RPM 60 Hz...

Page 2: ...toys utensils etc Sanitary Napkins or Tampons Diapers Rags Disposable Wipes or Cloth Medications Flammable Material Oil or Grease Strong Chemicals Gasoline Risk of electric shock To reduce risk of el...

Page 3: ...Steel CUTTER Stainless Steel SHAFT Stainless Steel SQUARE RINGS Buna N HARDWARE Stainless Steel PAINT Powder Coated Industrial Grade SEAL Single Mechanical Carbon Ceramic Buna N UPPER BEARING Single r...

Page 4: ...3450 17 0 53 0 F SOW 12 3 67 PFGPC2022HHSA 2 60 230 1 3450 15 0 53 8 H SOW 12 3 67 Specifications Dimensions MODEL HP Volts Ph BREAKER SIZE VOLTAGE RELAY START CAPACITOR RUN CAPACITOR High Volume PFG...

Page 5: ...12 Vane Vortex Bronze SHREDDING RING Stainless Steel CUTTER Stainless Steel SHAFT Stainless Steel SQUARE RINGS Buna N HARDWARE Stainless Steel PAINT Powder Coated Industrial Grade POWER CORD 20 ft Cus...

Page 6: ...ns Dimensions MODEL HP Volts Ph BREAKER SIZE VOLTAGE RELAY START CAPACITOR RUN CAPACITOR High Volume PFGPC2002HV 2 200 1 30 Amp internal MARS 169 internal 150 mfd 250v internal 20 mfd 450v PFGPC2022HV...

Page 7: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 7 Performance PFGPC HH HHS 2HP Submersible Grinder Pumps BACK TO INDEX...

Page 8: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 8 Performance PFGPC HV HVS 2HP Submersible Grinder Pumps BACK TO INDEX...

Page 9: ...Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve and a shu...

Page 10: ...chambers for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor and bearings d Inspect seal for wear or leakage Servicing NOTE Item numbers in...

Page 11: ...te for oil expansion Apply pipe thread compound to threads of pipe plug 4 then assemble to motor housing 15 Check that o ring 24 is in place and does not need to be replaced Reassemble upper housing t...

Page 12: ...k rotor for wear If rotor or the stator windings are defective the complete motor must be replaced Inner Seal Double Remove seal 53 rotating member and spring from rotor shaft Press stationary from in...

Page 13: ...ith lockwashers 11 into seal plate and torque to 6 5 ft lbs Outer Seal Single Double Clean and oil stationary seal cavity in bearing bracket 21A on Single Seal or 51 seal plate on Double Seal Slide se...

Page 14: ...e on threads and place into shaft and tighten Upper Housing Capacitors Assemble capacitors 14 16 and relay 13 to housing Place o ring 24 onto motor housing 15 Assemble gland nut 3 friction ring 46 and...

Page 15: ...lopumps com 15 Figure 10 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFGPC HVS HHS 2HP Singl...

Page 16: ...flopumps com 16 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFGPC HV HH 2HP Double Seal Subm...

Page 17: ...4 200 Volt 1 Ph PF081200S10 Motor Double Seal 230 volt 1 Ph PF110397BG 200 volt 1 Ph PF081200S06 18 1 6 Lower Bearing PF10 36 E4 19 1 Upper Housing PF105196CAP 20 1 6 Square Ring PF074498 21A 1 Bearin...

Page 18: ...r Clamp 7mm PF033459 46 2 Friction ring PF051450 47 1 Bronze Insert Double Seal Only 48 1 Pipe Plug 1 4 NPT Double Seal Only 49 4 Stud 5 16 18 x 2 1 4 Lg Stainless Double Seal Only 50 4 Hex Nut 5 16 1...

Page 19: ...equired Consult the factory Disconnect unit electrically Remove the pump from the basin Detach the pump base and clean the area around the impeller Rotate impeller by hand Reassemble and reinstall Pum...

Page 20: ...ained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydroca...