background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerfl opumps.com

4

MODEL

HP

Hz

Volts/Ph

RPM

Full Load 

Amps

Locked 

Rotor Amps

NEMA Start 

Code

Cord 
Type

Cord 

Size

Cord 

O.D.

High Volume

PFG2002HV*

2

60

200/1

3450

17.0

53.0

F

SOW

12/4

.67

PFG2022HV*

2

60

230/1

3450

15.0

53.8

H

SOW

12/4

.67

PFG2062HV

2

60

200/3

3450

11.0

42.0

J

SOW

12/4

.67

PFG2032HV

2

60

230/3

3450

9.0

36.0

J

SOW

12/4

.67

PFG2042HV

2

60

460/3

3450

4.0

18.0

J

SOW

12/4

.67

High Head

PFG2002HH*

2

60

200/1

3450

17.0

53.0

F

SOW

12/4

.67

PFG2022HH*

2

60

230/1

3450

15.0

53.8

H

SOW

12/4

.67

PFG2062HH

2

60

200/3

3450

11.0

42.0

J

SOW

12/4

.67

PFG2032HH

2

60

230/3

3450

9.0

36.0

J

SOW

12/4

.67

PFG2042HH

2

60

460/3

3450

4.0

18.0

J

SOW

12/4

.67

(*) IMPORTANT!

  - These pumps require a control panel with start, run capacitors and relay. 

Capacitor kits which include Start & Run capacitors and Start relay, are available if a Power-Flo control panel is not used.
See page 13 for wiring schematic.
PF88243 - for 200 volt, 1 phase
PF73306 - for 230 volt, 1 phase

Specifi cations

MODEL

HP Volts/Ph

BREAKER

SIZE

HEATER

SIZE (**)

VOLTAGE

RELAY

START

CAPACITOR

RUN

CAPACITOR

High Volume

PFG2002HV

2

200/1

30 Amp

K-60

MARS 169

150 mfd - 250 volts

20 mfd - 450 volts

PFG2022HV

2

230/1

30 Amp

K-57

MARS 169

150 mfd - 250 volts

45 mfd - 450 volts

PFG2062HV

2

200/3

20 Amp

K-53

N/R

N/R

N/R

PFG2032HV

2

230/3

20 Amp

K-50

N/R

N/R

N/R

PFG2042HV

2

460/3

15 Amp

K-33

N/R

N/R

N/R

High Head

PFG2002HH

2

200/1

30 Amp

K-60

MARS 169

150 mfd - 250 volts

20 mfd - 450 volts

PFG2022HH

2

230/1

30 Amp

K-57

MARS 169

150 mfd - 250 volts

43 mfd - 450 volts

PFG2062HH

2

200/3

20 Amp

K-53

N/R

N/R

N/R

PFG2032HH

2

230/3

20 Amp

K-50

N/R

N/R

N/R

PFG2042HH

2

460/3

15 Amp

K-33

N/R

N/R

N/R

N/R = Not Required
Winding resistance ± 5% at terminal block.   Rated operation at ± 10% voltage at motor.
(**) Recommended heater sizes may very depending on pump station requirements.

PFG - HH & HV 2HP 

 

 

 

  

      

        Submersible Grinder Pumps

BACK TO INDEX

Summary of Contents for PFG2002HH

Page 1: ...ISP No PFGrinder 9 09 INSTALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFG2002HV HH PFG2022HV HH PFG2062HV HH PFG2032HV HH PFG2042HV HH Double Seal 2...

Page 2: ...ood Shells Aquarium Gravel Cat Litter Plastic Objects toys utensils etc Sanitary Napkins or Tampons Diapers Rags Disposable Wipes or Cloth Medications Flammable Material Oil or Grease Strong Chemicals...

Page 3: ...AFT Stainless Steel SQUARE RINGS Buna N HARDWARE Stainless Steel PAINT Powder Coated Industrial Grade SEAL Tandem Double Mechanical Carbon Ceramic Buna N UPPER BEARING Single row Ball Oil Lubricated I...

Page 4: ...vailable if a Power Flo control panel is not used See page 13 for wiring schematic PF88243 for 200 volt 1 phase PF73306 for 230 volt 1 phase Specifications MODEL HP Volts Ph BREAKER SIZE HEATER SIZE V...

Page 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 Performance PFG HH 2HP Submersible Grinder Pumps BACK TO INDEX...

Page 6: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 6 Performance PFG HV 2HP Submersible Grinder Pumps BACK TO INDEX...

Page 7: ...not pump out of liquid Controls PFG series grinders require a separate approved pump control device or panel for automatic operation Be sure the electrical specification of the control selected proper...

Page 8: ...tential problems can be corrected It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of the motor housing or a minimum level o...

Page 9: ...ashlight visually inspect the oil in the housing 15 to make sure it is clean and clear light amber in color and free from suspended particles Milky white oil indicates the presence of water Oil level...

Page 10: ...ounter clockwise to remove CAUTION Cutter edges are very SHARP Cutter must be removed before removing volute Volute Remove hex nuts 41 from studs 34 and remove volute 25 from pump Shredding Ring To re...

Page 11: ...g should come in contact with the seal face except the seal tool Be sure the stationary is in straight Place seal s 19 retaining ring and spring over shaft until seated on shaft shoulder Slide a bulle...

Page 12: ...mage the seal face With seal guide tool over motor shaft Lightly oil Do not use grease guide shaft and inner surface of bellows on rotating seal With lapped surface of rotating member facing inward to...

Page 13: ...Figure 7 200 240 Volt 3Phase Figure 7 460 Volt 3Phase Figure 7 200 230 Volt 1Phase Pump Wiring Schematics PFG HH HV 2HP Submersible Grinder Pumps 1Phase Capacitor Relay Pack For Control Panels 2HP 20...

Page 14: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 14 Typical Panel Wiring Schematic PFG HH HV 2HP Submersible Grinder Pumps BACK TO INDEX...

Page 15: ...w powerflopumps com 15 Figure 8 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFG HH HV 2HP Su...

Page 16: ...w powerflopumps com 16 Figure 9 PFG HH HV 2HP Submersible Grinder Pumps Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number...

Page 17: ...Seal Carbon Ceramic Buna N PF111131 20 1 6 Square Ring PF074498 21 1 Bearing Bracket PF108879 22 1 Pipe Plug 1 4 NPT 23 1 Bronze Insert 24 1 6 Square Ring PF067564 25 1 Volute PF108344 26 3 Pump Leg...

Page 18: ...6 Retaining Ring PF061143 40 1 6 Impeller Screw 1 4 20 x 3 4 Lg Stainless PF070704 41 4 Hex Nut 5 16 18 Stainless Repair Kits CUTTER KIT Includes Item numbers 27 28 29 40 PFG2HV CT PFG2HH CT 6 OVERHAU...

Page 19: ...uired Consult the factory Disconnect unit electrically Remove the pump from the basin Detach the pump base and clean the area around the impeller Rotate impeller by hand Reassemble and reinstall Pump...

Page 20: ...ned in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarb...

Reviews: