SD700FL SERIES
POWER ELECTRONICS
20
MECHANICAL INSTALLATION
5.
MECHANICAL INSTALLATION
CAUTION
The installation must be done by qualified personal.
Otherwise, it could lead to people injury and cause damaged to the equipment.
5.1.
Environmental ratings
It is recommended to follow the instructions of this manual to ensure the correct operation of the drive.
The installer has the responsibility of a properly indoor installation to ensure the ambient conditions of the
VFD. Additionally, the installer is ultimate responsible of the local regulation fulfilment. The environmental
ratings are the following ones:
Environmental category:
Indoor
Wet locations:
No
Pollution degree:
PD3
Drive ingress protection rating:
Clean zone: Electronics IP54 or IP20
Power connection and Input RFI filters: IP20
Filter ingress protection rating:
Frames 1 to 4: IP20
Frames 5 to 11: IP42
Operation Ambient temperature:
-20ºC to 50ºC Heavy duty
-20ºC to 40ºC Normal Duty
Storage Ambient temperature:
-40ºC to 70ºC
Humidity:
10 % to 95 % (non condensing)
Heating resistors:
Optionals
Maximum altitude and power derating:
1000m 1% PN(kW) per 100m; 4000m maximum
Vibration (IEC60068-2-6):
Deflection 0.075mm at 10Hz-57Hz
Acceleration 9.8m/s² at 57Hz-150Hz
Audible Noise:
< 79dB
Overvoltage category:
III
Protection class:
Class 1
Painting:
Standard colour RAL 7047 in the front part and
RAL 7016 in the rear part, other under request.