![Power Electronics SD700FL Series Hardware And Installation Manual Download Page 24](http://html1.mh-extra.com/html/power-electronics/sd700fl-series/sd700fl-series_hardware-and-installation-manual_1586650024.webp)
SD700FL SERIES
POWER ELECTRONICS
22
MECHANICAL INSTALLATION
5.3.
Clearances
The SD700FL must be installed in vertical position, and firmly fastened through the dedicated
anchorages placed in the rear part of the drive that avoid any movement.
If the equipment is installed inside a cabinet, ensure that the hot air expelled from the drive is evacuated
outside. This hot air can be aspirated again so the drive may suffer from overheating. To ensure a
suitable cooling avoid the recirculation of air and keep the minimum clearance distances indicated below.
Figure 5.3 Minimum clearances for frames 1 to 4
Figure 5.4 Minimum clearances for frames 5 to 11 (Frame 5)
FRAME
DISTANCE (mm)
FRONT
CLEARANCE
A
B
C
1
200 200
5
700
2
200 200
5
800
3
200 200
35
800
4
300 300
35
820
FRAME
DISTANCE (mm)
FRONT
CLEARANCE
A
B
5
400
80
930
6
400
80
940
7
400
80
1260
8
400
80
1260
9
400
80
940
10
400
80
1260
11
400
80
1260