1.6. Protection
Power
Limited to 3kW in any feedback
configuration
Inverter output current
Limited to 70A peak. Short circuit
protected.
Resonant capacitor voltage
Limited to 350V rms
Line current
20A Circuit breaker
Temperature and cooling
Air-cooling provide by three fans.
Heatsink temperature switch for
protection.
Safety Interlocks
Emergency stop button or door switch
opens the main circuit breaker.
1.7. Load
Quality factor of load
Will operate with any load Q (including
resistive loads), provided that the
output frequency and voltage is within
the specifications.
1.8. Cooling Water
Maximum pressure
100PSI
(690kPa)
Minimum differential pressure
30PSI
(207kPa)
Minimum water flow
.5GPM
(0.032l/s)
Maximum inlet water temperature
105
°
F
(41
°
C)
Minimum water resistivity
590
Ω
.in (1500
Ω
.cm)
Supply hose location
Back of Cabinet
5