6.2. Changing the heat station components.
This section describes the procedures for changing the heat station components.
6.2.1. Series inductor.
The turn selector bar is identified by
c
in Figure 4 on page 16. The near position selects zero
turns and the far position eleven turns, as indicated in Figure 4 on page 16. Tighten the bar
into position using the mounting screws.
The shorting bar has to be used for finer adjustment of the series inductance during the tuning
(section 6.1. on page 15) of the heat station.
Example: If the initial setup was for 4 turns (shorting bar not installed), and the turns needs to
be decreased with a quarter turn, install the shorting bar in the low (3) position. If the shorting
bar reaches the high (1) position and the inductance still needs to be decreased, remove the
shorting bar completely and move the turns bar one position forward, e.g. from the 4 turns
position to the 3 turns position.
1
Turn selector bar (0 -11 turns)
2
Variable shorting bar
WARNING:
Make sure that the
circuit breaker is turned off before
adjusting heat station components.
Figure 4: Adjusting the Series Inductor
16