Sirius FS
56
GB/IE
7.3.10 High Temperature Burner Door Limit Thermostat
-
See section 7.2 (item 3) for access
- Remove the front access door using a flat bladed screwdriver to release
the catches at the top of the door. Lift the top of the door outwards and
then upwards to remove it
- Unplug electrical connectors from either side of the thermostat
- Unscrew body of thermostat from heat exchanger door
- Replacement is the reverse
Before operating the boiler after replacement of this thermostat, inspect the insulation
attached to the inside of the heat exchanger door , to ensure that it is complete and
undamaged. Failure to do so could result in permanent damage.
7.3.11 Spark Generator
-
See section 7.2 (item 3 for access)
- Remove the front access door using a flat bladed screwdriver to release
the catches at the top of the door. Lift the top of the door outwards and
then upwards to remove it.
- Unplug the power connector and ignition lead from unit
- Remove screws fixing the generator to the metal back plate
- Remove unit
- Replacement is the reverse
Ignition lead
Power connector
Fixing screws