Sirius FS
40
GB/IE
Note: After successful adjustment of the gas valve, the CO
2
content must again be
confirmed at both low and high load output. Adjustment of the maximum output rate
will also change the minimum output rate. Adjust rate at low and high output if
necessary.
Too high a CO
2
value can lead to incomplete combustion, high CO values and
damage to the burner.
Too low a CO
2
value can lead to ignition problems
In case of installation in areas with fluctuating natural gas composition, the CO
2
contents
should be adjusted in accordance with the Wobbe Index at any given time (refer to gas
supply company).
The CO
2
content can be decided as follows:
CO
2
content = 9.3 -(W
o
N
- W
o
current
) * 0.5
6.4 DECOMMISSIONING, DISPOSAL AND RECYCLING
Only qualified competent persons should decommission and dismantle the appliance.
Before dismantling and removing please ensure you safely remove the power supply and
isolated the appliance from the water and gas connections.
Dispose of the appliance correctly according to the laws and regulations in force. The
appliance and accessories cannot be discarded along with normal household waste and
should be recycled where appropriate.
More than 90% of the materials that make up the appliance are recyclable.