4.0 Technical Data
© Baxi Heating UK Ltd 2016
0
200
400
600
800
1000
1200
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head
0
5
5.5
6
4.5
4.1
Promax Ultra 24, 28, 33, 40 Combi
Flue Terminal
Diameter
100mm
Dimensions
Projection
125mm
Outercase Dimensions
Casing Height
- 763mm
Overall Height Inc Flue Elbow
- 923mm
Casing Width
- 450mm
Casing Depth
- 355mm
Weights
(24/28)
Packaged Boiler Carton
41.5kg
Installation Lift Weight
36kg
(33)
Packaged Boiler Carton
43.5kg
Installation Lift Weight
38kg
(40)
Packaged Boiler Carton
44.5kg
Installation Lift Weight
39kg
Central Heating Primary Circuit
Pressures
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended Operating Range
1-2
DHW Circuit
bar
Pressures
Max Operating
8
Min Operating
0.15
Flow Rates
(24)
(28)
(33)
(40)
l/min l/min
l/min
l/min
DHW Flow Rate
@ 30
o
C Rise
10.9
12.9
15.3
18.3
DHW Flow Rate
@ 35
o
C Rise
9.8
11.5
13.5
16.4
Min Working
DHW Flow Rate
2
2
2
2
Pump
Available Head
See graph below
Expansion Vessel
-
(For Central Heating only.
Integral with appliance)
bar
Min Pre-charge Pressure
0.5
(24 & 28)
(33 & 40)
litre
litre
Max Capacity of
CH System
125
125
Primary Water Content
of Boiler (unpressurised)
2.5
2.8
Connections
copper tails
Gas Inlet
-
22mm
Heating Flow
-
22mm
Heating Return
-
22mm
Cold Water Inlet
-
15mm
Hot Water Outlet
-
15mm
Pressure Relief Discharge
-
15mm
Temperatures
C.H. Flow Temp
(adjustable)
25°C to 80°C
max
(± 5°C)
D.H.W. Flow Temp
(adjustable)
35°C to 60°C
max
(± 5°C)
dependent upon flow rate
NOx Class
5
Clearances
Above Casing
175 mm Min
Below Casing
150 mm* Min
Front
450 mm Min
(For Servicing)
Front
5 mm Min
(In Operation)
L.H. Side
5 mm Min
R.H. Side
5 mm Min
*This is MINIMUM recommended dimension. Greater
clearance will aid installation and maintenance.
Heat Input CH Qn Hs (Gross)
Max
Min
24 model
kW
22.20
3.89
28 model
kW
26.64
4.32
33 model
kW
31.08
5.33
40 model
kW
35.52
6.55
Heat Output CH (Non-Condensing)
Max
Min
24 model
kW
20.0
3.4
28 model
kW
24.0
3.8
33 model
kW
28.0
4.7
40 model
kW
32.0
5.7
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Electrical Protection
IPX5D
Internal Fuse Rating
F2L
Appliance Category
CAT I
2H 3P
Injector
24 model
mm
4.4
28 model
mm
4.6
33 model
mm
4.9
40 model
mm
5.8
Heat Output CH (Condensing) Pnc
Max
Min
24 model
kW
21.2
3.7
28 model
kW
25.3
4.1
33 model
kW
29.6
5.1
40 model
kW
33.8
6.2
Heat Input DHW Qnw Hs (Gross)
Max
24 model
kW
27.4
28 model
kW
32.1
33 model
kW
37.8
40 model
kW
45.8
Heat Output DHW
Max
24 model
kW
24
28 model
kW
28
33 model
kW
33
40 model
kW
40
Condensate Drain
To accept 21.5mm (
3
/
4
in) plastic waste pipe
External Fuse Rating
3A
Power Consumption
24 model
W
85
28 model
W
90
33 model
W
95
40 model
W
100
Inlet Pressure
(Natural Gas - G20)
mbar
20
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
24 model
m
3
/h
2.61
28 model
m
3
/h
3.05
33 model
m
3
/h
3.59
40 model
m
3
/h
4.35
Inlet Pressure
(Propane - G31)
mbar
37
NATURAL GAS ONLY !
PROPANE ONLY !
Max Gas Rate
(Propane - G31)
(After 10 mins)
24 model
kg/h
1.96
28 model
kg/h
2.29
33 model
kg/h
2.70
40 model
kg/h
3.27
NOTE:
All data in this section are nominal values
and subject to normal production tolerances.
IMPORTANT:
Where Low Flow Taps or Fittings are
intended to be used in the DHW system connected it is
strongly recommended that the DHW flow rate DOES
NOT fall below 2.5l/min. This will ensure reliable
operation of the DHW function.
SAP 2009 Annual Efficiency for N. G.
models is 89.1%
SAP 2009 Annual Efficiency for L.P.G.
models is 90.1%
This value is used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calculated
has been certified by 0085.
Product Characteristics Database (SEDBUK)
Appliance Type
C
13
C
33
C
43
C
53