![Potterton Kingfisher Mf CFL40 - 100 Installation & Service Instructions Manual Download Page 26](http://html.mh-extra.com/html/potterton/kingfisher-mf-cfl40-100/kingfisher-mf-cfl40-100_installation-and-service-instructions-manual_1583053026.webp)
Publication No. 5102977
26
CON0029G
Service & Replacement of Parts
4.1
General Access
Warning: Before attempting to remove any
component from the appliance first disconnect
the mains electricity supply by removing the
plug from the wall socket or by switching off the
appliance at the external isolating switch.
Notes: The 'O' (stand-by) position on the boiler
temperature control will leave parts of the boiler
Live.
If the appliance gas valve is to be removed it will
be necessary to isolate the gas supply at the
appliance isolating valve.
Important: After removal or replacement of
any gas carrying component a test for gas
soundness must be made and functional check
of the controls carried out.
Re-assemble all parts in reverse order.
1. Remove the plinth - 2 screws.
2. Remove the front cover - 2 screws, lower
and lift away.
3. Remove the controls panel - open flap,
remove screw, unhook, disconnect the in-
line connector and lift away.
4. Remove the top cover - 2 screws, pull
forward and lift off. (Top blanking plate
should be removed - CFL only).
5. For better access, the controls tray can
slide forward.
a. Loosen 2 screws at front of tray.
b. Slide tray forward until rear of tray
reaches front.
c. Tilt tray up and pull out.
d. Carefully slide wires to either side of
tray.
e. Place rear hole slots into screws
loosened in 5a.
Fig. 25
Summary of Contents for Kingfisher Mf CFL40 - 100
Page 13: ...Publication No 5102977 13 CON0093B Installation Requirements Fig 8 Fig 7 ...
Page 14: ...Publication No 5102977 14 Installation Requirements Fig 9 Fig 10 ...
Page 31: ...Publication No 5102977 31 Fig 30 Pictorial Wiring Diagram CON0082B T T B CFL Models Only ...
Page 34: ...Publication No 5102977 34 Fault Finding ...