Installation
Fig. 19
2.3
Connect the Gas Supply
1. Ensure that the gas supply is isolated.
2. Disconnect the gas cock from the gas valve.
3. Connect the gas supply to the gas cock
using a suitable adaptor.
Important:
Do not solder the fitting whilst
assembled to the gas cock.
The pipe diameter required will depend on
the boiler model and the pipe length from
the gas meter. Ensure that the gas supply
pipe is selected in accordance with BS 6891
so that an adequate gas supply to the boiler
is provided.
4. Connect the gas cock to the gas valve.
Do not turn the gas supply on at this stage.
2.4
Connect the Water System
When attaching the standard pipe connecting kit to the boiler please note that the seal is made by use of an 'O' ring,
therefore some pipe movement will be evident even though a water tight seal has been achieved. Excessive force is
not necessary and could result in damage to the appliance.
1. Connect system pipework to the boiler, compression fittings should be used. Arrange pipework to ensure correct venting
of pipes and boiler. On gravity systems a tee is required in the flow which must be fitted directly to the connecting pipe
supplied. Note: Drain off taps should be installed at the lowest points in the system.
2. If on a Gravity DHW system position the overheat thermostat as shown.
3. To do this - unscrew the overheat thermostat from the flow pipe and re-attach as shown using the bracket and screw
found in the tail pipe/gravity stat kit.
C
O
N
0
02
5B
Gas Pipe
Installed
Gas
Cock
Gas Cock
Rc ½"
½" B.S.P.
Female
Gas
Valve
Connect Gas Pipe
Stage
1
Stage
2
'ON'
'OFF'
Disconnect
Gas Cock
from the
Gas Valve
Return
(Pumped)
Return
(Pumped)
CON0020D
Fig. 18
Summary of Contents for Kingfisher Mf CFL40 - 100
Page 13: ...Publication No 5102977 13 CON0093B Installation Requirements Fig 8 Fig 7 ...
Page 14: ...Publication No 5102977 14 Installation Requirements Fig 9 Fig 10 ...
Page 31: ...Publication No 5102977 31 Fig 30 Pictorial Wiring Diagram CON0082B T T B CFL Models Only ...
Page 34: ...Publication No 5102977 34 Fault Finding ...