iHE
36
153
Unit manually locked
Reset button stuck in
160
Fan speed threshold not reached
Required fan speed not reached - Faulty fan unit
171
Alarm contact 1 active
Condensate blockage
172
Alarm contact 2 active
Alarm 2 activated (not con
fi
gured)
173
Alarm contact 3 active
Alarm 3 activated (not con
fi
gured)
174
Alarm contact 4 active
Alarm 4 activated (not con
fi
gured)
217 Sensor error
Ionisation current fault.
317
Mains frequency outside permissable range
Check electrical installaiton
320 DHW Charging temperature, sensor error
Check connections and / or replace faulty sensor (B36)
324
Input BX, same sensors
BX sensor duplicated - check parameters
325
Input BX/extension module, same sensors
BX extension module sensor duplicated - check parameters
326
Input BX/mixing group, same sensors
Bx Mixing Circuit sensor duplicated - check parameters
327
Extension module, same function
Extension Modules duplicated - check parameters
330
Sensor input BX1 without function
BX1 connected but not de
fi
ned - check parameters
331
Sensor input BX2 without function
BX2 connected but not de
fi
ned - check parameters
332
Sensor input BX3 without function
BX3 connected but not de
fi
ned - check parameters
333
Sensor input BX4 without function
BX4 connected but not de
fi
ned - check parameters
335
Sensor input BX21 without function
BX21 connected but not de
fi
ned - check parameters
336
Sensor input BX22 without function
BX22 connected but not de
fi
ned - check parameters
351
Primary controller/system pump, address error
Htg Pump (Q14) not con
fi
gured on PCB1
353 Cascade
fl
ow sensor B10 missing
Check connections and con
fi
guration of sensor (B10)
384
Extraneous Light
Ionisation current detected before ignition
385
Mains under voltage
Mains voltage below 185v - check installation
386
Fan speed tolerance
Fan outside allowed speed tolerance level - replace fan
388
DHW sensor no function
Tank temperature sensor not con
fi
gured (B3)
432
Function earth not connected
No Ignition earth, X1 / X17 not connected or earth fault
NA
Operating mode button locked - Cannot operate
Remote system enable operating. Check Link terminals
in DHW or Heating mode (No fault code displayed)
Code Fault Description
Notes
Table 3.0
FAULT CODES (CONTINUED)