The next configuration screen allows for the setting of system delay times for the fill, dose, and drain functions.
The
Tank Full Sensor Delay
controls the amount of time the system will keep filling or dosing once 100% level is
reached to ensure the system is full.
The
Auto Dosing Error Delay
is a setting that determines the amount of the time the system is allowed to try
to fully dose the machine automatically. If the machine does not register as full before this configured time a
Dosing Error
alarm will become active.
The
Auto Draining Error Delay
is a setting that determines the amount of time the system is allowed to try
to fully drain the machine automatically. If the machine does not register as empty before this configured time a
Draining Error
alarm will become active.
6. Appendix A
The next configuration screen allows for the setting of the system level that will trigger the Auto-Level feature
if enabled.
The
Auto Dosing Tank Level
setting controls at which level the auto-level feature will become active during an
auto cycle if enabled.