PostProcess Technologies, Inc. • www.postprocess.com • REV A | page 15
Standby
– Because heat is an important component of post-processing, the DECI has functionality built-in to
allow the detergent to be maintained at a certain temperature when the machine is not in use. The
AUTO-
TEMPERATURE
button should be enabled if the tank needs to be kept at a constant temperature between
cycles. If
AUTO-TEMPERATURE
is not enabled, the DECI tank heater will need to be run manually to bring the
temperature up to the desired level before starting the cycle.
Auto-Drain
– When enabled, the tank will automatically drain after the completion of a user defined amount of
auto cycles.
Auto-Level
- When enabled, the tank level will be monitored at a user defined interval. If the tank level drops
below a predefined level the tank will be automatically dosed back to 100%. A message will appear to inform the
operator.’
Auto-pH
- When enabled, the tank’s pH will be monitored. If the pH falls below the Minimum Operational pH Level
a warning will become active and the tank will be automatically drained and re-dosed to correct the pH level. A
message will appear to inform the operator.
Advanced Output
– If enabled, system data is collected for
PostProcess
Support.
Light Stack Test
– When pressed the light stack will illuminate so the operator can verify that the lights are
operational. The light stack should be tested at the beginning of each shift.
Power
– When pressed a menu will appear for restarting the PC, shutting down the PC, or exiting the application.
1.3.4 Setting Standby Operation
Temp Setpoint
– Use the slider bar to set the desired tank temperature for Auto-Temperature mode.
Temperature Check Wait Time
– Sets the time between temperature checks while in Auto-Temperature mode.
Press the
LEFT ARROW
to return to the
Features
screen.
Figure 10.
Auto-Temperature Configuration
Screen
Once the
AUTO-TEMPERATURE
is enabled, the operator can adjust the
Auto-Temperature Configuration
settings.
To access the settings, press the “right arrow” from the
Features Enabling Screen.
1. Operation
Press the
X
button
to exit the
Auto-
Temperature
screen.
A confirmation will
display.