21 – 45
Error correction level 4 32
46 – 100
Error correction level 5 64
101 – 200
Error correction level 6 128
201 – 400
Error correction level 7 256
401 or more
Error correction level 8
512
5.
Settings of this function are effective until
ESC @
is executed, the printer is
reset, or the power is turned off.
CODES
(HEX/CONTROL):
<1D> <28>
<
6B
> <03> <00> <30> <46>
<n>
/ {GS} ( k
pL
pH
cn
fn n
<Function 70>
NAME: PDF417: Select the options
FUNCTION: PDF417: Select the options
RANGE:
pL
=
3
,
pH = 0, cn= 48, fn=70, m
= 0,1,
m
= 0
EXPLANATION:
m Function
0
Selects the standard PDF417.
1
Selects the truncated PDF417.
1.
Settings of this function affect the processing of Functions 081 and 082.
2.
Settings of this function are effective until
ESC @
is executed, the printer is
reset, or the power is turned off.
CODES
(HEX/CONTROL):
<1D> <28>
<
6B
> < p > < pH> <30> <50>
<n>
/ {GS} ( k
pL
pH
cn
fn n
<Function 80>
NAME:
PDF417: Store the data in the symbol storage area
FUNCTION:
PDF417: Store the data in the symbol storage area
RANGE:
4
≤
(
p
L
+
p
H
256)
≤
65535 (0
≤
p
L
≤
255, 0
≤
p
H
≤
255)
cn
= 48
fn
= 80
m
= 48
0
≤
d
≤
255
k
= (
p
L
+
p
H
256)
– 3
EXPLANATION:
Stores the PDF417 symbol data (
d1...dk
) in the symbol storage area.
1. The symbol data saved in the symbol archive area by this function is encoded
Command Manual - Page 40