![POSIFLEX AURASeries Command Manual Download Page 20](http://html.mh-extra.com/html/posiflex/auraseries/auraseries_command-manual_1582370020.webp)
position of the printable area:
When the starting position is set to the upper left or lower right of the
printable area using {ESC} T, the vertical motion unit
y
is used.
When the starting position is set to the upper right or lower left of the print
able area using {ESC} T, the horizontal motion unit
x
is used.
CODES
(HEX/CONTROL)
:
<
1B
> <
3D
> / {
ESC
} =
NAME: Set peripheral device
FUNCTION: Set peripheral device
RANGE:
1
≤
n
≤
3, default n=1
EXPLANATION:
1. Selects device to which host computer sends data, using n as follows:
Bit Off/On Hex Decimal Function
Off 00
0 Printer
disabled.
0
On 01
1 Printer
enabled
1-7 -
-
-
Undefined.
2. When the printer is disabled, it ignores all data except for error-recovery
commands (
DLE EOT, DLE ENQ, DLE DC4
) until it is enabled by this
command.
CODES
(HEX/CONTROL):
<1B> <3F> <
n>
/ {ESC} ?
n
NAME:
Cancels user-defined characters
FUNCTION:
Cancels user-defined characters
RANGE:
20
≤
n
≤
126
EXPLANATION:
1. This command cancels the pattern defined for the character code specified by
n
, after the user-defined characters is canceled, the corresponding pattern for
the internal character is printed.
2. If a user-defined character has not been defined for the specified character
code, the printer ignores this command.
Command Manual - Page 20