5. In page mode, this command is not effective.
CODES
(HEX/CONTROL):
<1C> <71> <
n>
[<
xL> <xH> <yL> <yH>
<d1> …<d
k
>
]
1
…
[<
xL> <xH> <yL> <yH> <d1> …<d
k
>
]
n
/ {FS} q
n
[
xL xH yL yH d1 … d
k
]
1
…
[
xL xH yL yH d1 … d
k
]
n
NAME:
Define NV bit image
FUNCTION:
Define the NV bit image
RANGE:
1
≤
n
≤
255 0
≤
d
≤
255
0
≤
xL
≤
255 0
≤
xH
≤
3 1
≤
(
xL+ xH
x 256)
≤
1023
0
≤
yL
≤
255 0
≤
yH
≤
1 1
≤
(
yL+ yH
x 256)
≤
288
k = (
xL+ xH
x 256) x (
yL+ yH
x 256) x 8
Total defined data area = 2M bits (256K bytes)
EXPLANATION:
1. The parameter
n
specifies number of NV bit images defined.
xL, xH
specifies [
xL
+
xH
x 256] x 8 dots in the horizontal direction for the NV
bit image you are defining.
yL,
yH
specifies[y
L
+ y
H
x 256] x 8 dots in the vertical direction for the NV bit
image you are defining.
2. This command works only when processed at the beginning of a line in text
mode.
3. In page mode, this command does not work. The data received are treated as
normal data to print.
4. Frequent redefining NV bit image may cause damage in the NV memory.
Therefore, it is recommended to write the NV memory less than 10 times a day.
5. This command cancels all NV bit images that have already been defined by
this command. The printer cannot redefine only part of definitions previously
defined. In this case, all data needs to be sent again.
6. Example:
To define image #1 and image #2 as
and
Command Manual - Page 34