In diving operations, the use of oxygen is essential for the 

human metabolism. In addition, oxygen concentration levels 

greater  than  in  air,  can  improve  safety,  especially  but  not 

only, by lowering the risk for DCS and Nitrogen narcosis.

The  Poseidon  Xstream  Deco/Oxygen  is  approved  for  use 

with  gaseous  oxygen  up  to  99.95  %  purity  at  maximum 

300 bar supply  pressure  and  a maximum  gas  temperature 

of 60˚C. The Poseidon Xstream Duration90/Duration/Dura-

tion EN 144-3 is also approved for use with gaseous oxygen 

up to 99,95 % purity at maximum 300 bar supply pressure 

and a maximum gas temperature of 60˚C

Using gaseous mixtures containing oxygen at high pressure 

always presents a certain level of risk for equipment failure 

due  to  combustion.  Greater  concentration  oxygen,  greater 

pressure, greater temperature, respectively represents fac-

tors that contributes to increase the mentioned risk.

Therefore, Poseidon has taken every precaution using “sta-

te  of  the  art”  technology,  expertise,  industrial  standards, 

and  knowledge  to  lower  the  risk  as  far  as  possible.  Both 

Xstream  Deco  /  Oxygen  and  Xstream  Duration  are  engi-

neered  for  oxygen  use,  assembled  and  cleaned  in  a  clean 

room environment, made up by materials chosen to expose 

lowest possible risk x failure-effect product, and are tested 

and approved for oxygen use.

It  is  strictly  prohibited  to  use  the  Poseidon  Xstream  Oxy-

gen/Deco/Duration/Duration90  with  oxygen  (ref.  “defini-

tions”) without being fully trained and certified in the use 

of oxygen by a recognised training agency. Failure to have 

such training and certification could lead to death or serious 

personal injury.

It is likewise absolutely essential that the end user strictly 

follows the mandatory guidelines given in the users manual 

for the Xstream models. Regular maintenan-

ce,  servicing  and  cleaning  is  a  prerequisite 

for keeping the risk as low as possible.

Servicing  and  cleaning  must  be  carried  out 

by an authorised oxygen service dealer. Po-

seidon has developed and verified a servicing 

and  cleaning  method,  which  guarantee  ac-

ceptable levels of contaminations. Poseidon 

can not be held responsible for the effects of 

other un-verified cleaning and servicing methods.

Failure  to  adhere  to  these  mandatory  requirements  trans-

fers the responsibility to the owner.

Poseidon will continue to develop products and components 

which further readuses the risks involved with oxygen use. 

Releasing  such  products  and  components  is  not  an  admit-

tance that previously released items must be recalled. It is 

in everyone’s interest to always strive for lowering risks.

OXYGEN STATEMENT

Summary of Contents for XSTREAM

Page 1: ...USER MANUAL ENGLISH XSTREAM...

Page 2: ...0 s The same ideas motivate us now The name Poseidon represents constant development and improvement of diving equipment where everything is positioned correctly and everything functions even in the m...

Page 3: ...Type approvement certificate no 020341 020342 and 020343 is issued by SGS United Kingdom Ltd Unit 202b Worle Parkway Weston super mare BS22 6WA United Kingdom Notified body number 0120 Production qua...

Page 4: ...ng greater than 21 oxy gen up to 50 Enriched Air Nitrox IP Interstage pressure the pressure existing between the 1st stage and the 2nd stage valve HP High pressure the pressure inside the SCUBA cylind...

Page 5: ...oxy gen content than 99 95 by volume Xstream Deep models only for use with air or Trimix with a maximum oxygen content of 21 and a maximum Helium content of 77 Xstream Dive and octopus only for use wi...

Page 6: ...r than 18 m 59 ft or in overhead environment requires special train ing regarding practices equipment physical and medical understanding This manual assumes the reader has some basic knowledge in thos...

Page 7: ...must be used exclusively with Nitrox or Oxygen and should be kept O2 clean at all times If a Oxygen Deco or Duration regulator is contaminated or used with a contaminated fill then the regulator must...

Page 8: ...medical effects or even death if used incorrectly Use recognised tables for oxygen exposure Xstream Oxygen EN 144 3 Deco Deco EN 144 3 is approved for oxygen service directly from the box i e it is cl...

Page 9: ...if it gets lost during the operation the regulator will continue to function but must only be used for immediate ascent In case of a malfunction in the 1st stage causing excessive intermediate pressur...

Page 10: ...extreme leaktightness Conventional designs are sensitive to wear misalignment and manufacturing precision A ball always finds its correct place Combined with the 2nd stage the enormous capacity of the...

Page 11: ...r of 0 C 32 F for at least 10 minutes and after wards still be completely unaffected DEEP DEEP90 1 ST STAGE TRIMIX AIR All materials in Xstream Deep are chosen and tested to be optimised for Helium an...

Page 12: ...d NVR levels less than ASTM G63 Level C 50 mg m2 hydrocarbons The Xstream Oxy90 1st stage is only used on the Mk VI Discovery Rebreather The Xstream Deco was discontinued in 2005 DURATION DURATION EN...

Page 13: ...e gas by as much as 12 C 22 F under certain conditions Using a long hose requires some basic knowledge in its use and routing to take the full advantages Poseidon does not recommend the use of hose pr...

Page 14: ...nnection areas with your fingers since fingerprints are a combustible con tamination OXYGEN ALERT PRE DIVE The procedure described below only describes the manner in which the regulator is assembled a...

Page 15: ...n the knob back half turn When the 2nd stage is pressurised and the servo mechanism engages a maximum of 3 litres of gas vents from the 2nd stage Slow opening of the cylinder valve is the best way to...

Page 16: ...ck for the regulator being used The mouth region can become numb from cold and you risk loosing the regulator DIVING What is most distinctive about the Xstream is that it is easy to use there aren t a...

Page 17: ...that the pro tective cap is free from water and debris then mount the protective cap onto the connection The regulator should not be stored in direct sunlight and or at high temperatures Make sure it...

Page 18: ...stream neck strap surgical cord Poseidon Jetstream 2nd stage and hose EN 250 Poseidon Jetstream 1st stage EN 250 All CE marked or EN 250 designated cylinder valves Yoke clamp All CE marked approved pr...

Page 19: ...t gas mix Always follow established calculation methods and mixing procedures for mixing a breathable gas These are not des cribed herein WARNING WARNING Approved gas mixes for Xstream Deep If air is...

Page 20: ...4351 psi Cold water perfor mance Exceeding EN 250 requirements for cold water use Approvals Type Approved acc to EU Direc tive Personal Protective Equipment 89 686 EEC Applicable Performan ce Standard...

Page 21: ...gical cord Silicone Dismountable w o tools Yes Anatomic Mouthpiece Poseidon AIR 1st stage Flowrate l min 4000 l min 141 scfm Nominal inter stage pres 8 5 bar 123 psi Anti Freeze protec tion Built in T...

Page 22: ...22 XSTREAM USER MANUAL ENGLISH M I S C E L L A N E O U S EXPLODED VIEWS With over pressure valve built in to the 1st stage No over pressure valve built in to the 1st stage...

Page 23: ...of the cylinder capa city The diagram above show a calculated graph for Work of Breathing in Joules litre at Qaverage 62 5 litres min The equation behind it is extracted from hundreds of tests from wh...

Page 24: ...regula tor free flows breaking the surface Check the cracking pressure see sec tion 6 2 If the crack ing pressure is too low it i n c r e a s e s the risk for free flow Have the re gulator cor rectly...

Page 25: ...room environment made up by materials chosen to expose lowest possible risk x failure effect product and are tested and approved for oxygen use It is strictly prohibited to use the Poseidon Xstream O...

Page 26: ...ised service loca tions Look for the POSEIDON Authorised Service Center sign SERVICE CENTER AUTHORIZED Because of the robustness and simplicity of the Xstream construction the amount of servicing is k...

Page 27: ...uct are prohibited Modifications can impair the function of the regulator and transfers the responsibility to the person who does the mo dification Adding decals and other outer means for oxygen Nitro...

Page 28: ......

Page 29: ...421 08 V stra Fr lunda SWEDEN t 46 0 31 7342900 f 46 0 31 7342901 www poseidon se Art no 4695 ISSUE 040924 3 WE INTEND TO CONTINUE TO PRODUCE DIVING EQUIPMENT AS LONG AS A SINGLE DROPOFWATERREMAINSINT...

Reviews: