USER MANUAL ::
ENGLISH
:: 13
XSTREAM
F
U
N
C
T
IO
N
DIVE90 1:ST STAGE (AIR)
Dive shares the performance and specifications
from the other Xstream 90 models. It is identified
by the chrome plated T.D.A. top and the number of
outlets: 5 low pressure and 2 highpressure.
Xstream Dive is delivered with a 70 cm hose, but
all hoses available for the Xstream regulator also
fits the Xstream regulator.
The Dive90 was discontinued 2005 and replaced with Deep90
XSTREAM LP HOSES
All Xstream hoses are made of high quality SBR/NR, and are av-
ailable in different lengths. For deep dives or in particularly cold
conditions a long hose 2.15m (7 ft) has the benefit of warming the
gas by as much as 12°C (22°F) under certain conditions.
Using a long hose requires some basic knowledge in its use and
routing, to take the full advantages.
Poseidon does not recommend the use of hose protectors on Po-
seidon IP hoses.
Hose protectors have been shown to mislead the user to neglect
the necessary pre-dive hose inspection. Therefore, Poseidon ho-
ses are fitted with wear preventing end crimps, which in addition
can be inspected for the full engagement of the hose to the insert
at any time through the inspection hole.
On Xstream specific hoses (article no 4680-XXX) the hose end at
the 2nd stage includes the safety valve. As a visible indication of a
fault, the excessive gas will bleed to the ambient environment.
The hose is available in the following lengths as standard
2.15m (7ft.)
1.50m (4.9 ft)
0.90m (3 ft)
0.70m (2.3 ft)
Xstream Dive90 1st stage
Summary of Contents for XSTREAM