S
Approved gas mixes for Dive:
Maximum level of:
Oxygen
21% by volume
CO
15 ppm
CO2
500 ppm
Water dew point
-35ºC (-31°F)
Lubricants (droplets/mist)
0.5 mg / m
3
Water
25 mg / m
3
Maximum Operational
depth
Certified to 200 m (656 ft)
Typical Work of Brea-
thing 50m on air, 62.5
l/min
1.5 J/l (see diagrams below)
Typical Work of brea-
thing 200m on Trimix,
62.5 l/min
1.7 J/l (see diagrams below)
Approved gas
Dive
Air
Deep
Air / Trimix
Duration
Air / EAN 50 /
Oxygen
Deco
Air / Oxygen
Maximum
working
pressure
300 bar (4351 psi)
Cold water perfor-
mance
Exceeding EN 250 requirements for
cold water use
Approvals
Type Approved acc. to EU Direc-
tive Personal Protective Equipment
89/686/EEC
Applicable Performan-
ce Standards
EN 738-1, clause 6.6, 6.6.2
NORSOK U-101 clause 5.2-5.5, 5.9
EN 250:2000
Cleaned to hydrocar-
bon levels < 50mg/
m2 & particle level X
Dive
No
Deep
No
Duration
Yes
Deco / Oxygen
Yes
O-ring materials
Dive
Nitrile, EPDM
Deep
Nitrile, EPDM
Duration
Viton, EPDM
Deco / Oxygen
Viton, EPDM
TECHNICAL DATA
Maximum level of:
Oxygen
99.95% by volume
CO
2 ppm
CO2
500 ppm
Water dew point
-45ºC (-50°F)
Lubricants (droplets/mist)
0.5mg/ m
3
Water
25 mg/ m
3
Gaseous hydrocarbons
15 ppm
Condensed hydrocarbons
0.1 mg/m
3
Solid particles
2 microns
Approved gas mixes for Xstream Deco/Duration/