background image

 

- ii -

Safety 

IMPORTANT SAFETY INSTRUCTIONS 

1.  To disconnect the machine from the electrical power supply, turn off the 

power switch and remove the power cord plug from the wall socket. The 
wall socket must be easily accessible and in close proximity to the 
machine. 

2.  Read these instructions carefully. Save these instructions for future 

reference. 

3.  Follow all warnings and instructions marked on the product. 
4.  Do not use this product near water. 
5.  Do not place this product on an unstable cart, stand, or table. The product 

may fall, causing serious damage to the product. 

6.  Slots and openings in the cabinet and the back or bottom are provided for 

ventilation to ensure reliable operation of the product and to protect it from 
overheating. These openings must not be blocked or covered. The 
openings should never be blocked by placing the product on a bed, sofa, 
rug, or other similar surface. This product should never be placed near or 
over a radiator or heat register or in a built-in installation unless proper 
ventilation is provided. 

7.  This product should be operated from the type of power indicated on the 

marking label. If you are not sure of the type of power available, consult 
your dealer or local power company. 

8.  Do not allow anything to rest on the power cord. Do not locate this product 

where persons will walk on the cord. 

9.  Never push objects of any kind into this product through cabinet slots as 

they may touch dangerous voltage points or short out parts that could result 
in a fire or electric shock. Never spill liquid of any kind on the product. 

 

CE MARK   

This device complies with the requirements of the EEC directive 
2004/108/EC with regard to “Electromagnetic compatibility” and 2006/95/EC 
“Low Voltage Directive”. 

 

FCC 

This device complies with part 15 of the FCC rules. Operation is subject to the 
following two conditions: 
(1) This device may not cause harmful interference.   
(2) This device must accept any interference received, including interference that 
may cause undesired operation. 

Summary of Contents for EVO-RD1-VFD

Page 1: ...Revision v1 2 November 2009 EVO RD1 VFD User Manual...

Page 2: ...particular purpose We shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This document co...

Page 3: ...t should never be placed near or over a radiator or heat register or in a built in installation unless proper ventilation is provided 7 This product should be operated from the type of power indicated...

Page 4: ...ction recycling and disposal procedure To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it respo...

Page 5: ...4 Set the string display mode and write string to display 31 4 5 Upper line message continuous scroll 31 4 6 Move cursor left 32 4 7 Move cursor right 32 4 8 Move cursor up 32 4 9 Move cursor down 32...

Page 6: ...5 x 7 Dot matrix Display color Blue green Brightness 700 cd m2 Character type 96 alphanumeric 25 international character sets Character size 9 0mm x 5 25mm Power supply 12V Power consumption 3 6 W MTB...

Page 7: ...etting 1 3 1 Command Type Selection SW1 SW2 SW3 Command Type Demo Mode Support Default ON ON ON POS7300 No OFF ON ON EPSON ESC POS Yes ON OFF ON ADM 787 ADM 788 No OFF OFF ON DSP800 Yes ON ON OFF AEDE...

Page 8: ...K I 5 OFF ON OFF ON OFF SWEDEN 6 ON OFF OFF ON OFF ITALY 7 OFF OFF OFF ON OFF SPAIN CP 858 Multilingual Euro Symbol 8 ON ON ON OFF OFF JAPAN Katakana 9 OFF ON ON OFF OFF NORWAY 10 ON OFF ON OFF OFF DE...

Page 9: ...an change the settings as follows 1 4 1 Baud Rate Setting Command STX 05 B n ETX Change the baud rate setting ASCII Format STX 05 B n ETX Dec Format 02 05 66 n 03 Hex Format 02h 05h 42h n 0 3 h 30h n...

Page 10: ...font n Character Set 20h 7Fh Code Table 80H FFH Note 30h U S A CP 437 USA Standard Europe 31h FRANCE 32h GERMANY 33h U K 34h DENMARK I 35h SWEDEN 36h ITALY 37h SPAIN CP 858 Multilingual Euro Symbol 3...

Page 11: ...e and initialize the display The display emulation mode is based on DSP800 ESC ADM 787 POS7300 AEDEX UTC CD5220 mode n Command Type n Command Type 30h POS7300 34h AEDEX 31h ESC POS 35h UTC P 32h ADM 7...

Page 12: ...ition O O O Move cursor to home position O O O Move cursor to bottom position O O Move cursor to specified position O O O O Clear display screen O O O O O Clear cursor line O O O Brightness adjustment...

Page 13: ...UTC S UTC P AEDEX ADM788 DSP800 Upper line message continuous scroll O O O O Bottom line message scroll continuously O Message vertical down scroll continuously O Message vertical upper scroll contin...

Page 14: ...line O O Clear field 1 and move cursor to field 1 first position O Clear field 2 and move cursor to field 2 first position O Clear display range from n position to m position and move cursor to n pos...

Page 15: ...roll continuously Maximal DATA length is 40 ESC P x y 1B 50 x y Move cursor to specified position x 1 14h for columns location y 1 2 for lines location ESC _ n 1B 5F n Set cursor on off n 00 01 ESC DC...

Page 16: ...Mode Command List 2 Command Code hex Function Description BS 08 Back space HT 09 Horizontal tab LF 0A Line feed HOM 0B Move cursor to home position CLR 0C Clear display screen CLR 12 Clear display scr...

Page 17: ...string to lower line 1 Maximal DATA length is 20 ESC Q D DATA CR 1B 51 44 DATA 0D Upper line message scroll continuously 1 2 Maximal DATA length is 40 ESD D 1B 5B 44 BS 08 Move cursor left ESC C 1B 5...

Page 18: ...1 x2 14h for columns location y 1 2 for lines location s 0 cancel s 1 set CLR 0C Clear display screen and clear string mode CAN 18 Clear cursor line and clear string mode ESC n 1B 2A n US X n 1F 58 n...

Page 19: ...many D 44h Denmark I I 49h Italy E 45h Denmark II J 4Ah Japan L 4Ch Slavonic U 55h U K R 52h Russia F 46h France S 53h Spain N 4Eh Norway 4 Select character code table 80H FFH by command ESC c n Param...

Page 20: ...d mode 2 3 5 UTC Enhanced Mode Command List Command Code hex Function Description ESC u A DATA CR 1B 75 41 DATA 0D Upper line display Maximal DATA length is 20 ESC u B DATA CR 1B 75 42 DATA 0D Bottom...

Page 21: ...scroll once pass Maximal DATA length is 40 2 3 7 ADM787 788 mode command list Command Code hex Function Description CLR 0C Clear display CR 0D Carriage return SLE1 0E Clear upper line and move cursor...

Page 22: ...rrent view message to n layer for demo view data n 31h 35h EOT SOH D n m ETB 04 01 44 n m 17 Display the saved demo message n 31h 4Fh m 31h 33h EOT SOH A n ETB 04 01 41 n 17 n 31h 34h Brightness adjus...

Page 23: ...3 n Set cursor on off n 00 01 BS 08 Move cursor left HT 09 Move cursor right US LF 1F 0A Move cursor up LF 0A Move cursor down US CR 1F 0D Move cursor to right most position CR 0D Move cursor to left...

Page 24: ...58 n Brightness adjustment n 1 4 ESC W n s x1 y1 x2 y2 1B 57 n s x1 y1 x2 y2 Set or cancel the window range n 1 4 for window number s 0 cancel s 1 set 1 x1 x2 14h for columns location 1 y1 y2 2 for li...

Page 25: ...an Latin 2h CP 850 Multilingual 9h CP 852 Hungary 11h Windows 1253 Greek 3h CP 860 Portuguese Ah CP 862 Hebrew 12h Windows 1250 East European Latin 4h CP 863 Canadian French Bh CP 866 Cyrillic 13h CP...

Page 26: ...07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 20h 30h 0 1 2 3 4 5 6 7 8 9 40h A B C D E F G H I J K L M N O 50h P Q R S T U V W X Y Z _ 60h a b c d e f g h i j k l m n o 70h p q r s t u v w x y Z 3 2 Character...

Page 27: ...h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h a o B0h C0h D0h l E0h F0h 1 3 2 3 2 3 CP 858 Multilingual Euro Symbol 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh...

Page 28: ...apan 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h IE IR x 1 x 1 A0h B0h C0h D0h E0h F0h 3 2 5 Slawie 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h...

Page 29: ...01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h Y Y 3 2 7 CP 860 Portuguese 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h a o...

Page 30: ...0h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h Y A0h s B0h C0h D0h E0h F0h 3 2 9 CP 852 Hungary 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h x A0h B0...

Page 31: ...w 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h 3 2 11 CP 863 Canadian French 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h...

Page 32: ...00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h Pt A0h a o B0h C0h D0h E0h F0h n 3 2 13 CP 866 Cyrillic 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h...

Page 33: ...250 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h 3 2 15 Windows 1251 Cyrillic 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h...

Page 34: ...est European Latin 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h 3 2 17 Windows 1253 Greek 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh...

Page 35: ...1255 Hebrew 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h 3 2 19 Windows 1257 Baltic 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 8...

Page 36: ...de In this mode the extent of the cursor activity is bound by a predefined range limited to the upper line Please refer to Set or cancel window command where the default window is the whole upper line...

Page 37: ...ite mode When the cursor has reached the right end of the lower line it will continue to the left end of the upper line and overwrite previous characters When it has reached the right end of the upper...

Page 38: ...d position of the current line 4 124 12 Move cursor to right most position The cursor will be moved to the right end position of the current line 4 134 13 Move cursor to bottom position The cursor wil...

Page 39: ...racters will be cleared and the string mode will be cancelled 4 184 18 Clear current line and cancel string mode The current line is cleared and the string mode is cancelled 4 194 19 Brightness adjust...

Page 40: ...1H DC1 02H STX MD2 12H DC2 03H ETX MD3 13H DC3 04H EOT MD4 14H DC4 05H ENQ MD5 15H NAK 06H ACK MD6 16H SYN 07H BEL MD7 17H ETB 08H BS MD8 18H CAN 09H HT 19H EM 0AH LF 1AH SUB 0BH VT HOM 1BH ESC 0CH FF...

Reviews: