background image

5 - ENG

D26126

HAZARD

HAZARD

HOW TO PREVENT IT

WHAT CAN HAPPEN

RISK TO BREATHING

AIR

OBTAINED DIRECTLY FROM THE

COMPRESSOR 

SHOULD NEVER BE USED TO

SUPPLY AIR FOR HUMAN CONSUMPTION.

IN

ORDER TO USE AIR PRODUCED BY THIS
COMPRESSOR FOR BREATHING, SUITABLE

FILTERS AND

IN-LINE 

SAFETY EQUIPMENT

MUST BE PROPERLY INSTALLED

. IN-LINE

FILTERS AND SAFETY EQUIPMENT

USED IN

CONJUNCTION WITH THE COMPRESSOR

MUST BE CAPABLE OF TREATING AIR TO
ALL APPLICABLE LOCAL AND FEDERAL
CODES PRIOR TO HUMAN CONSUMPTION.

WORK IN AN AREA WITH GOOD CROSS-
VENTILATION.  

READ AND 

FOLLOW THE

SAFETY INSTRUCTIONS

PROVIDED ON THE

LABEL OR SAFETY DATA SHEETS 

FOR THE

MATERIAL YOU ARE SPRAYING. USE A
NIOSH/MSHA APPROVED RESPIRATOR

DESIGNED FOR USE WITH YOUR SPECIFIC
APPLICATION.

THE 

COMPRESSED AIR

DIRECTLY FROM

YOUR COMPRESSOR 

IS NOT SAFE FOR

BREATHING

. THE 

AIR STREAM MAY

CONTAIN CARBON MONOXIDE, TOXIC
VAPORS, OR SOLID PARTICLES

FROM THE

TANK. 

BREATHING

THESE

CONTAMINANTS

CAN CAUSE SERIOUS INJURY OR DEATH.

SPRAYED MATERIALS

SUCH AS PAINT,

PAINT SOLVENTS, PAINT REMOVER,
INSECTICIDES, WEED KILLERS, MAY

CONTAIN HARMFUL VAPORS AND POISONS.

RISK OF ELECTRICAL SHOCK

HOW TO PREVENT IT

WHAT CAN HAPPEN

YOUR 

AIR COMPRESSOR IS POWERED BY

ELECTRICITY.  

LIKE ANY OTHER

ELECTRICALLY POWERED DEVICE, 

IF IT IS

NOT USED PROPERLY IT MAY CAUSE
ELECTRIC SHOCK.

REPAIRS 

ATTEMPTED

BY UNQUALIFIED

PERSONNEL CAN RESULT IN SERIOUS
INJURY OR DEATH BY ELECTROCUTION.

ELECTRICAL GROUNDING:  

FAILURE TO

PROVIDE ADEQUATE GROUNDING TO THIS
PRODUCT COULD RESULT IN SERIOUS
INJURY OR DEATH FROM ELECTROCUTION.

SEE GROUNDING INSTRUCTIONS.

NEVER OPERATE THE COMPRESSOR
OUTDOORS WHEN IT IS RAINING OR IN WET
CONDITIONS.

NEVER OPERATE COMPRESSOR WITH
PROTECTIVE COVERS REMOVED

OR

DAMAGED. 

ANY 

ELECTRICAL WIRING OR REPAIRS

REQUIRED ON THIS PRODUCT 

SHOULD BE

PERFORMED BY AUTHORIZED SERVICE
CENTER PERSONNEL

IN ACCORDANCE WITH

NATIONAL AND LOCAL ELECTRICAL CODES.

MAKE CERTAIN THAT THE ELECTRICAL
CIRCUIT

TO WHICH THE COMPRESSOR IS

CONNECTED 

PROVIDES PROPER

ELECTRICAL GROUNDING, CORRECT
VOLTAGE AND ADEQUATE FUSE
PROTECTION.

Summary of Contents for CF2600

Page 1: ..._______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instr...

Page 2: ...the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other mas...

Page 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Page 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Page 5: ...SE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AND POISONS RISK OF ELECTRICAL SHOCK...

Page 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Page 7: ...PERSONS PETS AND OBSTACLES KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES DO NOT OPERATE THE PRODUCT WHEN FATIGUED OR UNDER THE INFLUENCE OF ALCOHOL OR DRUGS STAY ALERT AT ALL TIMES NEVER DEF...

Page 8: ...arks UL CUL ETL CETL have been evaluated by OSHA certified indepenent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety DUTY CYCLE Porter Cable air compressors...

Page 9: ...tions The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This p...

Page 10: ...ion Refer to the Specification Chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage s...

Page 11: ...he tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and...

Page 12: ...r a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2...

Page 13: ...essure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to bui...

Page 14: ...ety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob...

Page 15: ...See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual...

Page 16: ...lant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 Reapply pipe sealant to o...

Page 17: ...ly 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank c...

Page 18: ...s if any must be paid by the purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center tha...