9
Poolex Platinium
Test conditions
90
120
155
Air
(1)
26°C
Water
(2)
26°C
INVERTER MODE
Heating power (kW)
12,2~2,78
15,1~3,47
20,93~5,23
Consumption (kW)
1,79~0,20
2,22~0,261
3,22~0,46
COP
(Coeff. of performance)
13,3~6,8
13,3~6,8
11,37~6,50
Air
(1)
26°C
Water
(2)
26°C
SILENCE MODE
Heating power (kW)
8,8~2,78
10,6~3,47
14,65~5,23
Consumption (kW)
1,11~0,209
1,34~0,261
1,77~0,46
COP
(Coeff. of performance)
13,3~7,9
13,3~7,9
11,37~8,29
Air
(1)
15°C
Water
(2)
26°C
INVERTER MODE
Heating power (kW)
9,03~2,09
12,1~2,80
15,50~3,88
Consumption (kW)
1,86~0,28
2,50~0,40
3,39~0,57
COP
(Coeff. of performance)
7,30~4,83
7,30~4,80
6,80~4,57
Air
(1)
15°C
Water
(2)
26°C
SILENCE MODE
Heating power (kW)
6,37~2,09
8,40~2,80
10,85~3,88
Consumption (kW)
1,15~0,286
1,53~0,379
1,86~0,57
COP
(Coeff. of performance)
7,30~5,50
7,30~5,50
6,80~5,83
Air
(1)
35°C
Water
(2)
27°C
Cooling capacity (kW)
5,01~2,83
6,48~4,00
10,85~5,03
Consumption (kW)
1,06~0,51
2,03~0,87
2,58~1,05
Avg, EER
(Energy Efficiency Ratio)
4,71~3,49
4,72~3,49
4,77~3,56
Maximum power (kW)
3,2
4,0
4,9
Maximum current (A)
14
18
22
Electricity supply
220~240V / 50Hz
Protection
IPX4
Heating temperature range
15°C~40°C
Cooling temperature range
8°C~28°C
Operating temperature range
-10°C~43°C
Unit dimensions (mm)
Ø 928 x 896
Unit weight (kg)
59
65
75
Sound pressure level at 1 m (dBA)
(3)
40~48
41~50
42~52
Sound pressure level at 10 m (dBA)
(3)
21~29
23~31
24~32
Hydraulic connection (mm)
PVC 50mm
Heat exchanger
PVC tank and titanium heating coil
Min. / Max. water flow rate (m³/h)
3,3 / 8,5
4,4 / 10,3
5,2 / 12,5
Compressor
Mitsubishi
Mitsubishi
Mitsubishi
Compressor type
Twin Rotary
Twin Rotary
Twin Rotary
Refrigerant
R32
Load loss (mCE)
1,1
1,1
1,1
Max, pool volume (m
3
)
(4)
≤60
≤75
≤95
Remote control
Wired LED monitor screen
Mode
Heating / Cooling / Silent
2.3 Technical specifications
2. Description
The technical specifications of our heat pumps are provided for information purposes only. We reserve the right to make changes without prior notice.
1
Ambient air temperature
2
Initial water temperature
3
Noise at 1 m, at 4 m and at 10 m in accordance with Directives EN ISO 3741 and EN ISO 354
4
Calculated for an in-ground private swimming pool covered with a bubble cover.