21
WARNING:
When the cooling mode switches to heating mode or vice-versa, the heat pump will restart
after 10 minutes.
Step 1:
Long press
3s
to switch on your pump.
Step 2:
Long press
3s
to switch from one mode to another until ECO Heating Mode is displayed.
Step 3:
Select the desired temperature by using the buttons
and
(15-40°C).
4. Use
WARNING:
Before starting, ensure that the filtration pump is operating correctly.
EXAMPLE:
If you have selected 28°C, your screen will display:
Once the symbol
stops
blinking, the required temperature
is validated and is replaced by the
water’s current temperature (25°
in our example).
Required
temperature
“Blinking”
Current water
temperature
Current outlet
temperature
When the incoming water temperature is less than or equal to the required temperature (setpoint tempera-
ture - 1°C), the heat pump will switch to heating mode. The compressor will stop when the temperature of
the incoming water is greater than or equal to the required temperature (setpoint tempe 1°C).
4. Use
4.5 ECO silence Mode
Useful information