When the incoming water temperature is higher or equal to the required temperature (setpoint temperature 

+ 1°C), the heat pump will switch to cooling mode. The compressor will stop when the temperature of the 

incoming water is less than or equal to the required temperature (setpoint temperature - 1°C). 

Step 1:

 

Long press 

 3s 

to switch on your pump.

Step 2:

 

Long press

 

 3s 

to switch from one mode to another until the Cooling Mode is displayed. 

Step 3:

 

Using buttons 

 and 

 select the required temperature (8-28°C).

WARNING: 

Before starting, ensure that the filtration pump is operating correctly.

4. Use

WARNING:

 When the cooling mode switches to heating mode or vice-versa, the heat pump will restart 

after 10 minutes.

EXAMPLE:

If you have selected 24°C, for example, your screen will display:

Once the symbol 

 stops 

blinking, the required temperature 

is validated and is replaced by the 

water’s current temperature (27° 

in our example).

Required 

 

temperature

Current water 

temperature

Current outlet

 

temperature

4.4  Cooling Mode

Useful information

Summary of Contents for Poolex Jetline Platinium 120

Page 1: ...MANUEL D INSTALLATION ET D UTILISATION de votre pompe à chaleur www poolstar fr PLATINIUM ...

Page 2: ...released into the surrounding area Before starting work the environment of the equipment should be checked to ensure that there is no risk of flammability No smoking signs must be posted 6 Ventilated area Make sure the area is in the open air or is properly ventilated before working on the system or performing hot work Some ventilation must be maintained during the duration of the work 7 Controls ...

Page 3: ...esult of many years of research in the field of design and production of heat pumps for swimming pools Our aim is to provide you with an exceptional high performance quality product We have produced this manual with the utmost care so that you get maximum benefit from your Poolex heat pump Thank you ...

Page 4: ... and does not exceed the maximum limits authorised for this particular product In the event of a defect and or malfunction of the heat pump the electricity supply must be discon nected and no attempt made to repair the fault Repairs must be undertaken only by an authorised technical service organisation using original replace ment parts Failure to comply with the above mentioned clauses may have a...

Page 5: ... 2 Operating mode selector 18 4 3 Heating Mode 19 4 4 Cooling Mode 20 4 5 ECO Silence Mode 21 4 6 Setting the clock 22 4 7 Programming Start Stop 22 4 8 Forced de icing function 22 4 9 LED function 22 4 10 Lock Unlock control panel 22 4 11 Enable WiFi 22 4 12 Status values 23 4 13 Check system parameters 24 4 14 Adjust system parameters 24 5 Operation 26 5 1 Operation 26 5 2 Servo control of circu...

Page 6: ...ware of all the instructions in the heat pump s installation manual as well as the technical specifications Under no circumstances install the equipment close to a source of heat combustible materials or a build ing s air intake If installation is not in a location with restricted access a heat pump protective grille must be fitted To avoid severe burns do not walk on pipework during installation ...

Page 7: ...is stopped Check the water flow rate every month and clean the filter if necessary During cleaning Switch off the equipment s electricity supply Close the water inlet and outlet valves Do not insert anything into the air or water intakes or outlets Do not rinse the equipment with water During repairs Carry out work on the refrigerant system in accordance with current safety regulations Brazing sho...

Page 8: ...ance with up to 80 energy savings compared to a conventional heating system Clean efficient and environmentally friendly R32 refrigerant Reliable high output leading brand compressor Wide hydrophilic aluminium evaporator for use at low temperatures User friendly intuitive remote control Heavy duty ABS shell anti UV treated and easy to maintain Designed to be silent Dual antifreeze system to avoid ...

Page 9: ... 3 56 Maximum power kW 3 2 4 0 4 9 Maximum current A 14 18 22 Electricity supply 220 240V 50Hz Protection IPX4 Heating temperature range 15 C 40 C Cooling temperature range 8 C 28 C Operating temperature range 10 C 43 C Unit dimensions mm Ø 928 x 896 Unit weight kg 59 65 75 Sound pressure level at 1 m dBA 3 40 48 41 50 42 52 Sound pressure level at 10 m dBA 3 21 29 23 31 24 32 Hydraulic connection...

Page 10: ...10 A G H I H B E F D C J 2 4 Unit dimensions 2 Description Dimensions in mm Model Jetline Platinium 90 120 155 A 896 B 153 C 15 D 928 E 482 F 291 G 64 H 93 5 I 90 ...

Page 11: ...panel 3 LED indicator 4 Fan support 5 Fan blade 6 Fan motor 7 4 way valve 8 Support 9 Compressor 10 Gas liquid separator 11 Base frame 12 Front panel 13 Fan protective grille 14 Control panel 15 Evaporator 16 Heat exchanger 17 Electric transformer 18 Electrical control box 19 Electronic expansion valve ...

Page 12: ...sary the unit may be raised by using suitable mounting pads designed to support its weight 5 Check that the unit is properly ventilated that the air outlet is not facing the windows of neighbouring buildings and that the exhaust air cannot return In addition provide sufficient space around the unit for servicing and maintenance operations 6 The unit must not be installed in an area exposed to oil ...

Page 13: ...cated under the pump In order to minimise the noise pollution associated with heat pump vibrations it can be positioned on vibration absorbing pads To do this you simply have to position a pad between each of the unit s feet and its support and then fix the heat pump to the support with suitable screws 3 Installation Valves 1 2 and 3 Bypass valves Valves 4 and 5 Regulating valves Recommended for f...

Page 14: ...for at least 2 hours before putting the hydraulic circuit into water 3 6 Hydraulic connection 3 Installation WARNING Installation must be carried out by a qualified engineer This section is provided for information purposes only and must be checked and adapted if necessary according to the actual installation conditions WARNING Do not run water through the hydraulic circuit for 2 hours after apply...

Page 15: ...that the water in the system is clean thus avoiding the operational problems associated with dirt or clog ging in the filter 3 Installation Half open valve Half open valve Open valve Open valve Key Key TOWARDS THE POOL Filtration Pump Filtration Pump Automated treatment system Automated treatment system TOWARDS THE POOL FROM THE POOL POOL POOL FROM THE POOL ...

Page 16: ...or a three phase system it is essential to connect the phases in the correct sequence If the phases are inverted the heat pump s compressor will not work In places open to the public it is mandatory to install an emergency stop button close to the heat pump Models Electricity supply Max current Cable diameter Protection Thermal magnetic D curve protection Jetline Platinium 90 1 phase 220 240V 1N 5...

Page 17: ...irculating pump Depending on the type of installation you can also connect a circulating pump to terminals P1 and P2 so that this operates in tandem with the heat pump 3 Installation 3 8 Electrical connection WARNING The heat pump s power supply MUST be disconnected before any operation WARNING Servo control of a pump whose power exceeds 5A 1000W requires the use of a power relay L N P1 P2 Connect...

Page 18: ... Timers Button Operating mode Water inlet temperature Water outlet temperature Clock Operating mode Heating Mode Select the heating mode for the heat pump to heat the water in your pool intelligently Cooling Mode Select the cooling mode for the heat pump to cool the water in your pool intelligently ECO Silence Mode Select the silence heating mode for the heat pump to heat the water at reduced spee...

Page 19: ... until the Heating Mode is displayed Step 3 Using buttons and select the required temperature 15 40 C WARNING Before starting ensure that the filtration pump is operating correctly WARNING When the cooling mode switches to heating mode or vice versa the heat pump will restart after 10 minutes EXAMPLE If you have selected 28 C your screen will display Once the symbol stops blinking the required tem...

Page 20: ... Cooling Mode is displayed Step 3 Using buttons and select the required temperature 8 28 C WARNING Before starting ensure that the filtration pump is operating correctly 4 Use WARNING When the cooling mode switches to heating mode or vice versa the heat pump will restart after 10 minutes EXAMPLE If you have selected 24 C for example your screen will display Once the symbol stops blinking the requi...

Page 21: ...LE If you have selected 28 C your screen will display Once the symbol stops blinking the required temperature is validated and is replaced by the water s current temperature 25 in our example Required temperature Blinking Current water temperature Current outlet temperature When the incoming water temperature is less than or equal to the required temperature setpoint tempera ture 1 C the heat pump...

Page 22: ...er into timer functions Step 2 If blinking press to active the Start timer Step 3 Adjust the hours with the buttons and Step 4 Press to switch to minutes Step 5 Adjust the minutes with the buttons and Step 6 Press to programme the stop time Step 7 If blinking press to active the Stop timer Step 8 Adjust the hours with the buttons and Step 9 Press to switch to minutes Step 10 Adjust the minutes wit...

Page 23: ...ater inlet temperature 30 99 C A02 Water outlet temperature 30 99 C A03 Ambient temperature 30 99 C A04 Discharge temperature 0 125 C A05 Suction temperature 30 99 C A06 Outside coil temperature 30 99 C A07 Inside coil temperature 30 99 C A08 The openness of the expansion valve A09 Reserved A10 Compressor current A A11 PCB temperature C A12 Fan motor current A A13 Compressor real frequency Hz A14 ...

Page 24: ...ess to return to the main screen If not operation for 60s it will be exited automatically Step 1 Keep pressing 3s on and until you enter the settings edition mode Step 2 First you need to enter the password 68 Press to set the first password digit Step 3 Press until you get a 6 Step 4 Press to set the second password digit Step 5 Press until you get a 8 Step 6 Press to confirm Step 7 Press and to ...

Page 25: ...d Do not adjust Reserved 26 Reserved Do not adjust Reserved 27 Working mode of electrical expansive valve during cooiling mode 0 ambient temp A03 1 real over heat temp parameter A05 A07 1 Adjustable 28 Filtration pump servo control mode 0 1 1 Adjustable Parameter 01 allows you to change the lost degree interval from the requested temperature so that the heat pump starts again Example If the value ...

Page 26: ...ting correctly in the heat pump and that the flow rate is adequate Remove any unnecessary object or tool from around the unit Operation 1 Activate the unit s power supply protection differential switch and circuit breaker 2 Activate the circulating pump if it is not servo controlled 3 Check the By Pass opening and the control valves 4 Activate the heat pump by pressing once on 5 Adjust the remote ...

Page 27: ... go into safe mode This means that there has been a leakage of refrigerant and that you must call a qualified technician to replace it 5 4 Antifreeze protection When the heat pump is on standby the system monitors the ambient temperature and the water tempera ture in order to activate the antifreeze programme if required The antifreeze programme is automatically activated when the ambient temperat...

Page 28: ...eat pump must be carefully cleaned with a vacuum cleaner and soft brush attachment Annual maintenance The following operations must be undertaken by a qualified person at least once a year Carry out safety checks Check the integrity of the electrical wiring Check the earthing connections Monitor the state of the pressure gauge and the presence of refrigerant WARNING Before undertaking maintenance ...

Page 29: ... plug and water pipes in order to drain any water from the heat pump Step 2 Open the By Pass valve Close the inlet and outlet valves Step 4 Screw back the drain plug and pipes or block them with rags so as to prevent any foreign bodies from getting into the circuit Finally protect the pump with its winter storage cover WARNING DISCONNECT THE POWER SUPPLY If a circulating pump is servo controlled b...

Page 30: ...actions to be taken Fault code examples 7 1 Breakdowns and faults WARNING Under normal conditions a suitable heat pump can heat the water in a swimming pool by 1 C to 2 C per day It is therefore quite normal to not feel any temperature difference in the system when the heat pump is working A heated pool must be covered to avoid any loss of heat Fault code 03 Fault code 21 Fault code 04 Fault code ...

Page 31: ...eplace inverter module Defective PCB Replace PCB 12 Exhaust temperature too high Insufficient refrigerant gas Readjust the refrigerant volume 15 Water inlet temperature error Sensor disconnected or defective Reconnect or replace sensor 16 Outside coil temperature error Sensor disconnected or defective Reconnect or replace sensor 18 Exhaust temperature error Sensor disconnected or defective Reconne...

Page 32: ... new purchase Your heat pump has reached the end of its life and you wish to dispose of it or to replace it Do not throw it in the rubbish bin A heat pump must be disposed of separately with a view to its reuse recycling or upgrading It contains substances that are potentially hazardous to the environment but which will be eliminated or neutralised by recycling YOU HAVE THREE SOLUTIONS 8 1 Recycli...

Page 33: ... agent that is unsuitable for the pool Malfunction or damage arising from conditions that are unsuitable for the equipment s purposes of use Damage arising from negligence accident or force majeure Malfunction or damage arising from the use of unauthorised accessories Repairs undertaken during the warranty period must be approved prior to being carried out by an authorised technician The warranty ...

Page 34: ...34 10 Appendices Poolex Platinium 90 Poolex Platinium 120 155 10 1 Wiring diagrams ...

Page 35: ...ckage Check fan motor air duct 128 Temp of radiating fin failure Radiating fin temp sensor short circuit or open circuit failure Replace the inverter module 257 Connection failure Inverter module doesn t receive the command of PCB Check the connection between the module and PCB 258 AC input lack of phase Input lack of phase Check the wire connection 260 AC input voltage too high Input three phase ...

Page 36: ...www poolstar fr ASSISTANCE TECHNIQUE www poolex fr 03 2020 ...

Reviews: